High-precision simultaneous measurement of 187Os, 186Os, and 184Os using 1013 O amplifiers and CDDs on NTIMS
文献类型:期刊论文
作者 | Wang, Guiqin2,6; Zeng, Yuling1,6; Qi, Liang3; Liu, Wengui4; Xu, Jifeng5 |
刊名 | ANALYTICA CHIMICA ACTA
![]() |
出版日期 | 2023-10-16 |
卷号 | 1278页码:10 |
关键词 | Os isotopes Small-size sample NTIMS 10(13) O amplifier CDD Static measurement |
ISSN号 | 0003-2670 |
DOI | 10.1016/j.aca.2023.341721 |
英文摘要 | High-precision measurements of Os-184/Os-188, Os-186/Os-188, and Os-187/Os-188 ratios are significant in the fields of geochemistry and cosmochemistry. However, no high-precision measurement technique exists for simultaneously obtaining all three ratios using a static method for samples with an Os content of <1 ng or (OsO3-)-Os-186 and (OsO3-)-Os-187 ion-beam intensities of <150 mV. This greatly limits research on rare samples with small sample sizes or low Os contents, such as Lunar, Martian, or old Earth samples. This paper reports a static method, which could achieve the simultaneous measurement of 9 Faraday cups (FCs) with high-signal/noise ratio 10(12) Omega amplifiers and 10(13) Omega amplifiers and two compact discrete dynodes (CDDs). By analyzing two calibration solutions, a and precision value of less than 3 parts per thousand (2RSD) could be achieved for Os-184/Os-188 ratios, even if the (OsO3-)-Os-184 was as low as 1000 cps. The precision values for the Os-186/Os-188 and Os-187/Os-188 ratios were similar and could be better than 0.066 parts per thousand (2RSD) when the intensities of (OsO3-)-Os-186 intensity and (OsO3-)-Os-187 were greater than 30 mV, which can be obtained with conventional 10(11) Omega amplifiers only at signals larger than 150 mV. Three geological reference materials were used in this study. The precision values of Os-184/Os-188, Os-186/Os-188, and Os-187/Os-188 ratios reached 2, 0.061, and 0.050 parts per thousand (2RSD), respectively, when the maximum Os amount was approximately 12 ng, and 87, 15, and 10 parts per thousand (2RSD), respectively, when the maximum Os amount was as low as approximately 66 pg. Additionally, our results show that changes in the volume of oxygen added during measurement can cause significant variations in the oxygen isotope composition. This static measurement method not only avoids the nonlinear signal change of the instrument during the analysis process but also realizes the accurate removal of the oxygen isobaric interference in the run, which could improve the precision of Os-184/Os-188, Os-186/Os-188, and Os-187/Os-188 ratios for small-size/low-signal samples. |
WOS研究方向 | Chemistry |
语种 | 英语 |
WOS记录号 | WOS:001064061900001 |
源URL | [http://ir.gig.ac.cn/handle/344008/74825] ![]() |
专题 | 同位素地球化学国家重点实验室 |
通讯作者 | Wang, Guiqin; Liu, Wengui |
作者单位 | 1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 2.CAS Ctr Excellence Comparat Planetol, Hefei 230026, Peoples R China 3.Chinese Acad Sci, Inst Geochem, Guiyang 550002, Peoples R China 4.China Univ Geosci, Wuhan 430074, Peoples R China 5.China Univ Geosci, Beijing 100083, Peoples R China 6.Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Isotope Geochem, Guangzhou 510640, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Guiqin,Zeng, Yuling,Qi, Liang,et al. High-precision simultaneous measurement of 187Os, 186Os, and 184Os using 1013 O amplifiers and CDDs on NTIMS[J]. ANALYTICA CHIMICA ACTA,2023,1278:10. |
APA | Wang, Guiqin,Zeng, Yuling,Qi, Liang,Liu, Wengui,&Xu, Jifeng.(2023).High-precision simultaneous measurement of 187Os, 186Os, and 184Os using 1013 O amplifiers and CDDs on NTIMS.ANALYTICA CHIMICA ACTA,1278,10. |
MLA | Wang, Guiqin,et al."High-precision simultaneous measurement of 187Os, 186Os, and 184Os using 1013 O amplifiers and CDDs on NTIMS".ANALYTICA CHIMICA ACTA 1278(2023):10. |