Quantitative redox measurements for hydrothermal experiments conducted in cold-seal pressure vessels

文献类型:期刊论文

作者Fang, Jing2,3; Chou, I-Ming1; Audetat, Andreas2; Zhang, Lipeng3,4
刊名CHEMICAL GEOLOGY
出版日期2024-09-20
卷号663页码:9
关键词Hydrothermal experiment Oxygen fugacity Cold-seal pressure vessel Oxygen buffer Redox sensor
ISSN号0009-2541
DOI10.1016/j.chemgeo.2024.122286
通讯作者Fang, Jing(kfangjing@126.com) ; Chou, I-Ming(imchou@idsse.ac.cn)
英文摘要The cold-seal pressure vessel (CSPV) is a commonly-used apparatus for hydrothermal experiments performed at crustal temperature (T)-pressure (P) conditions. The redox states of the samples in CSPV hydrothermal experiments are normally controlled by the pressure medium, by using oxygen buffers, or with the Shaw membrane technique. Although these techniques have been widely used, the actual redox states of the samples are not necessarily the expected values and need to be quantitatively measured. In this study, by using CoPd, NiPd, and (NiMn)O redox sensors, quantitative redox measurements have been conducted in H2O-pressurized Ni-superalloy (Inconel 713 LC) CSPVs at 700-800 degrees C and 200 MPa. Oxygen fugacities (fO2) of the H2O pressure medium in three CSPVs used in this study were measured, and their log fO2 values were - 13.11 +/- 0.06 (Ni-NiO (NNO) + 0.7), - 13.05 +/- 0.06 (NNO + 0.8) and - 12.68 +/- 0.07 (NNO + 1.1), comparable with those reported previously. By placing an open capsule containing Ni powder below the sample capsule, the fO2 of the H2O pressure medium can be adjusted to reach that of the NNO buffer (NNO to NNO + 0.2). For the MnO-Mn3O4, Ni-NiO, and Co-CoO oxygen buffers, a steady-state fO2 was always achieved for each buffer at a fixed P-T condition. Measured log fO2 values for the Ni-NiO and Co-CoO buffers are in good agreement with theoretical values calculated from thermodynamic data and also with previous results obtained from vessels pressurized with Ar. The log fO2 values determined for the MnO-Mn3O4 buffer, about 0.3 log unit lower than the theoretical values, are consistent with previous values obtained from vessels pressurized with Ar. These results suggest that the use of H2O pressure medium would not perturb the equilibrium redox states of the oxygen buffers. In addition, we developed a miniature sensor that is small enough to be loaded together with other sample material, allowing the monitoring of fO2 in actual experiments.
WOS关键词HIGH-TEMPERATURES ; THERMODYNAMIC DATA ; AQUEOUS FLUIDS ; OXYGEN BUFFERS ; DEGREES-C ; CALIBRATION ; SOLUBILITY ; OXIDATION ; FUGACITY ; SULFUR
资助项目Sino-Germany (CSC-DAAD) Postdoctoral Scholarship ; China Postdoctoral Science Foundation[2021M703242] ; National Natural Science Foundation of China[42130109] ; National Natural Science Foundation of China[42303036] ; Natural Science Foundation of Shandong Province[ZR202211170176]
WOS研究方向Geochemistry & Geophysics
语种英语
WOS记录号WOS:001282639700001
出版者ELSEVIER
源URL[http://ir.qdio.ac.cn/handle/337002/186174]  
专题海洋研究所_深海极端环境与生命过程研究中心
通讯作者Fang, Jing; Chou, I-Ming
作者单位1.Chinese Acad Sci, Inst Deep Sea Sci & Engn, CAS Key Lab Expt Study Under Deep Sea Extreme Cond, Sanya 572000, Hainan, Peoples R China
2.Univ Bayreuth, Bayer Geoinst, D-95440 Bayreuth, Germany
3.Chinese Acad Sci, Ctr Deep Sea Res, Inst Oceanol, Qingdao 266071, Peoples R China
4.Laoshan Lab, Lab Marine Geol, Qingdao 266237, Peoples R China
推荐引用方式
GB/T 7714
Fang, Jing,Chou, I-Ming,Audetat, Andreas,et al. Quantitative redox measurements for hydrothermal experiments conducted in cold-seal pressure vessels[J]. CHEMICAL GEOLOGY,2024,663:9.
APA Fang, Jing,Chou, I-Ming,Audetat, Andreas,&Zhang, Lipeng.(2024).Quantitative redox measurements for hydrothermal experiments conducted in cold-seal pressure vessels.CHEMICAL GEOLOGY,663,9.
MLA Fang, Jing,et al."Quantitative redox measurements for hydrothermal experiments conducted in cold-seal pressure vessels".CHEMICAL GEOLOGY 663(2024):9.

入库方式: OAI收割

来源:海洋研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。