中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Vertical profile of PCDD/Fs in soil and sediment around an abandoned e-waste dismantling site

文献类型:期刊论文

作者Su, Xiaotong; Zhang, Yucheng; Tam, Nora F. Y.; Lao, Xiaolan; Zhong, Meiling; Wu, Qihang; Fei, Yingheng; Lei, Huifang; Chen, Zihui; Mai, Bixian
刊名JOURNAL OF SOILS AND SEDIMENTS
出版日期2023
卷号23期号:2页码:902-910
关键词DIBENZO-P-DIOXINS PCBS PCDD/PCDF HEALTH FURANS NORTH
ISSN号1439-0108
DOI10.1007/s11368-022-03340-7
英文摘要Purpose Informal electronic waste (e-waste) recycling has been identified as a significant source of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), which pose a health and environmental danger. The impact of PCDD/Fs in the e-waste dismantling sites depends on their concentration in environmental matrices. This study aimed to investigate the vertical distribution characteristic of PCDD/F content collected from an abandoned e-waste dismantling site in Guiyu, China, as well as the nearby paddy field and stream. Material and methods One year after the e-waste dismantle site was abandoned, soil, sediment, and mud cores were taken from the site, the neighboring stream, and the paddy field. The source and distribution characteristics of PCDD/Fs in samples were revealed using a variety of statistical analytic methods. Results and discussion The concentrations of PCDD/Fs steadily decreased with increasing soil depth at all sampling sites. The highest concentration of PCDD/Fs was discovered in the sub-layer (10-20 cm) of the e-waste disposal site, at 263,332.72 ng/kg. PCDD/Fs concentrations in soil, sediment, and mud samples were 314.21-16,037.39, 0.01-0.11, and 6.93-97.44 ng I-TEQ/kg, respectively, according to the International Toxicity Equivalency Quantity (I-TEQ). The health risk assessment revealed the harsh working environment for the workers. The association between the three sampling sites was determined using principal component analysis (PCA) and hierarchical cluster analysis (HCA). The main source of PCDD/Fs was e-waste recycling, and one of the explanations for the similarity of PCDD/Fs distribution between the non-plough layer (0-20 cm) of paddy field and sediments was thought to be water management. Conclusion Decades of informal e-waste recycling have led to PCDD/Fs reaching deep into the soil. The order of pollution levels was as follows: e-waste dismantling site > paddy field > stream. The utilization of the e-waste dismantling site and its neighboring lands necessitates meticulous planning and oversight.
WOS研究方向Environmental Sciences ; Soil Science
语种英语
WOS记录号WOS:000857272300002
源URL[http://ir.gig.ac.cn/handle/344008/80395]  
专题有机地球化学国家重点实验室
推荐引用方式
GB/T 7714
Su, Xiaotong,Zhang, Yucheng,Tam, Nora F. Y.,et al. Vertical profile of PCDD/Fs in soil and sediment around an abandoned e-waste dismantling site[J]. JOURNAL OF SOILS AND SEDIMENTS,2023,23(2):902-910.
APA Su, Xiaotong.,Zhang, Yucheng.,Tam, Nora F. Y..,Lao, Xiaolan.,Zhong, Meiling.,...&Chen, Laiguo.(2023).Vertical profile of PCDD/Fs in soil and sediment around an abandoned e-waste dismantling site.JOURNAL OF SOILS AND SEDIMENTS,23(2),902-910.
MLA Su, Xiaotong,et al."Vertical profile of PCDD/Fs in soil and sediment around an abandoned e-waste dismantling site".JOURNAL OF SOILS AND SEDIMENTS 23.2(2023):902-910.

入库方式: OAI收割

来源:广州地球化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。