A study on the determination of the metabolites of 2,4,6-Trinitrotoluene using a dual-drift tube ion mobility spectrometer
文献类型:期刊论文
作者 | Zhang, Xu1,2; Luo, Yuanjiang1,2; Xia, Lei2![]() ![]() ![]() ![]() |
刊名 | TALANTA
![]() |
出版日期 | 2025 |
卷号 | 281 |
关键词 | TNT Metabolites Ion mobility spectrometry Dual-drift tube |
ISSN号 | 0039-9140 |
DOI | 10.1016/j.talanta.2024.126857 |
通讯作者 | Xia, Lei(lxia@cmpt.ac.cn) ; Huang, Chaoqun(cqhuang@aiofm.ac.cn) |
英文摘要 | 2,4,6-Trinitrotoluene (TNT) and its four metabolites, namely 2-ADNT, 4-ADNT, 2,4-DANT, and 2,6-DANT, are highly toxic substances. These metabolites also serve as biomarkers for assessing the health of individuals exposed to TNT. In this study, a homemade DDT-IMS apparatus was utilized to detect these metabolites. Under negative detection mode, the drift times of 2-ADNT and 4-ADNT showed subtle shifts within a drift tube temperature range of 100 C-degrees-120 C-degrees, aiding in their differentiation. In positive detection mode for 2,4-DANT and 2,6-DANT, significant variations were observed in both the number and drift time of their positive product ions across a drift tube temperature range of 80 C-degrees-120 C-degrees. Consequently, optimal analytical performance for these metabolites was achieved at approximately 100 C-degrees. Evaluation of the instrumental response during the measurement of the four metabolites in both positive and negative modes revealed that negative detection mode offered greater advantages of detecting these compounds. The working ranges for measuring the four metabolites spanned two orders of magnitude, with detection limits for each metabolite nearly below 1 ng. Notably, clear identification of the signals for these metabolites was achieved even when samples were mixed in urine, highlighting the ability of the DDT-IMS in detecting TNT metabolites. The developed DDT-IMS detection method has significant potential for enhancing environmental risk assessment and biological hazard evaluation, particularly in relation to human exposure to TNT. |
WOS关键词 | URINARY METABOLITES ; GAS-CHROMATOGRAPHY ; HEMOGLOBIN ADDUCTS ; EXPLOSIVES ; TEMPERATURE |
资助项目 | National Natural Science Foundation of China[62171433] ; National Natural Science Foundation of China[22073100] ; National Natural Science Foundation of China[22076190] ; National Natural Science Foundation of China[22376198] ; National Natural Science Foundation of China[22306187] ; HFIPS Director's Fund[YZJJ202305-CX] ; HFIPS Director's Fund[YZJJ202405-TS] ; HFIPS Director's Fund[BJPY2021B08] ; Anhui Provincial Key R D Program[2022a05020034] ; Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument[2023BMP05] |
WOS研究方向 | Chemistry |
语种 | 英语 |
WOS记录号 | WOS:001312167500001 |
出版者 | ELSEVIER |
资助机构 | National Natural Science Foundation of China ; HFIPS Director's Fund ; Anhui Provincial Key R D Program ; Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/135272] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Xia, Lei; Huang, Chaoqun |
作者单位 | 1.Univ Sci & Technol China, Hefei 230026, Peoples R China 2.Chinese Acad Sci, Hefei Inst Phys Sci, Inst Hlth & Med Technol, Anhui Prov Key Lab Med Phys & Technol, Hefei 230031, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Xu,Luo, Yuanjiang,Xia, Lei,et al. A study on the determination of the metabolites of 2,4,6-Trinitrotoluene using a dual-drift tube ion mobility spectrometer[J]. TALANTA,2025,281. |
APA | Zhang, Xu.,Luo, Yuanjiang.,Xia, Lei.,Song, Yu.,Li, Wanjun.,...&Chu, Yannan.(2025).A study on the determination of the metabolites of 2,4,6-Trinitrotoluene using a dual-drift tube ion mobility spectrometer.TALANTA,281. |
MLA | Zhang, Xu,et al."A study on the determination of the metabolites of 2,4,6-Trinitrotoluene using a dual-drift tube ion mobility spectrometer".TALANTA 281(2025). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。