Improved Static Capacity Configuration for Hybrid Power Supply Scheme With Energy Storage Based on NSGA in Tokamak

文献类型:期刊论文

作者Tian, Yunxiang2,3; Wu, Yanan2,3; Lu, Jing2,3; Li, Jun2; Xu, Liuwei2,3; Zhang, Yang1; Wang, Pengfei2,3; Mao, Huafeng2
刊名IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
出版日期2024-03-01
卷号60
关键词Energy storage hybrid power supply scheme non-dominated sorting genetic algorithm (NSGA) static capacity configuration tokamak fusion power converter
ISSN号0093-9994
DOI10.1109/TIA.2023.3333766
通讯作者Wu, Yanan(wyn@ipp.ac.cn)
英文摘要Power impact frequently occurs during operation of shock loads, such as fusion devices, threatening the stable operation of the power system. Meanwhile, both short-time high pulse and long-time steady power exist, which have distinct time scales and amplitude characteristics. Currently, the capacity of power supply system is designed according to the maximum impulse power, causing the large redundancy and high cost. Aiming at this issue, hybrid power supply scheme based on energy storage technology with high power density provides a potential approach. However, little research focuses on the reasonable static configuration for different type of power supply. This paper presents the non-dominated sorting genetic algorithm (NSGA) algorithm to divide the two kinds of power, where impulse power can be treated by high-density energy storage and stable power is sustained by substation devices. In specific, taking the static investment and dynamic response of energy storage as the objectives, the critical optimal power can be determined. Finally, power scenario based on a typical Tokamak fusion device, international thermos-nuclear experimental reactor (ITER), is applied as case study of the proposed algorithm. The results show that the obtained crucial power can reasonably decrease the static capacity for substation to achieve the optimal economy and satisfy the mentioned objectives, providing the basis for other static capacity allocation circumstances and assisting accurate and high-efficiency smart control for power converters.
WOS关键词MULTIOBJECTIVE OPTIMIZATION ; DESIGN ; SYSTEM
资助项目Natural Science Foundation of China
WOS研究方向Engineering
语种英语
WOS记录号WOS:001191215500141
出版者IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
资助机构Natural Science Foundation of China
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/136018]  
专题中国科学院合肥物质科学研究院
通讯作者Wu, Yanan
作者单位1.Nanchang Inst Technol, Nanchang 330099, Peoples R China
2.Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
3.Univ Sci & Technol China, Hefei 230026, Peoples R China
推荐引用方式
GB/T 7714
Tian, Yunxiang,Wu, Yanan,Lu, Jing,et al. Improved Static Capacity Configuration for Hybrid Power Supply Scheme With Energy Storage Based on NSGA in Tokamak[J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS,2024,60.
APA Tian, Yunxiang.,Wu, Yanan.,Lu, Jing.,Li, Jun.,Xu, Liuwei.,...&Mao, Huafeng.(2024).Improved Static Capacity Configuration for Hybrid Power Supply Scheme With Energy Storage Based on NSGA in Tokamak.IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS,60.
MLA Tian, Yunxiang,et al."Improved Static Capacity Configuration for Hybrid Power Supply Scheme With Energy Storage Based on NSGA in Tokamak".IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS 60(2024).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。