On-line hydropyrolysis gas chromatography-mass spectrometry (HyPy-GC-MS) for kerogen-bound biomarkers
文献类型:期刊论文
作者 | Wang, Fu4,5,6; Liao, Yuhong4,5,6; Hsu, Chang Samuel1,2,3 |
刊名 | ORGANIC GEOCHEMISTRY
![]() |
出版日期 | 2025-02-01 |
卷号 | 200页码:11 |
关键词 | Bound biomarker Kerogen Hydropyrolysis Py-GC-MS Hydrogen Flash pyrolysis |
ISSN号 | 0146-6380 |
DOI | 10.1016/j.orggeochem.2024.104927 |
英文摘要 | Flash pyrolysis gas chromatography-mass spectrometry (Py-GC-MS) is seldom used to release bound biomarkers, because its hydrogen-poor pyrolysis conditions usually result in a low yield of bound biomarkers and high concentrations of olefins. In this study, by using a Py-GC-MS system and immature kerogen/coal samples, we investigated the effects of heating rate (flash versus 30 degrees C/min), carrier/reaction gas (He versus H-2), hydrogen pressure, and catalyst [(NH4)(2)MoO2S2] on the yields and distributions of bound biomarkers. Also, the bound biomarkers obtained by different pyrolysis conditions were compared with those from catalytic offline hydropyrolysis (HyPy) and free biomarkers from extracted organic matter (EOM). We propose a new technology of hydropyrolysis-gas chromatography-mass spectrometry (HyPy-GC-MS) to be used to release bound biomarkers. HyPy-GC-MS using low-pressure H-2 at slow heating rate can increase the yield of bound biomarkers by 3-9 times, minimize the cracking of the hopanes side chain, better preserve the original sterane and terpane distributions, and have characteristics of lower maturity, compared with conventional flash Py-GC-MS without H-2. Additionally, the steroidal and terpenoid yields by HyPy-GC-MS using low-pressure H-2 at slow heating rate from immature kerogens were 3-6 times that by HyPy. Compared with EOM, biomarker maturity parameter derived from HyPy-GC-MS may not fully represent the actual maturity of samples. Higher hydrogen pressure can significantly facilitate the hydrogenation of unsaturated hydrocarbons into saturated hydrocarbons, but it can also decrease the yields of pyrolysates with higher carbon numbers (i.e., >C-25), leading to a change in the biomarker ratios related to carbon numbers (e.g., the proportion of C-27-C-28-C-29 alpha alpha alpha 20R steranes and TT23/H-30 ratio). |
WOS研究方向 | Geochemistry & Geophysics |
语种 | 英语 |
WOS记录号 | WOS:001408491100001 |
源URL | [http://ir.gig.ac.cn/handle/344008/82606] ![]() |
专题 | 有机地球化学国家重点实验室 |
通讯作者 | Liao, Yuhong |
作者单位 | 1.China Univ Petr, State Key Lab Heavy Oil Proc, Beijing 102249, Peoples R China 2.Florida State Univ, Florida A&M Univ, Dept Chem & Biomed Engn, Tallahassee, FL 32310 USA 3.Petro Bio Oil Consulting, Tallahassee, FL 32312 USA 4.Univ Chinese Acad Sci, Yuquan Rd, Beijing 100049, Peoples R China 5.CAS Ctr Excellence Deep Earth Sci, Guangzhou 510640, Peoples R China 6.Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou 510640, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Fu,Liao, Yuhong,Hsu, Chang Samuel. On-line hydropyrolysis gas chromatography-mass spectrometry (HyPy-GC-MS) for kerogen-bound biomarkers[J]. ORGANIC GEOCHEMISTRY,2025,200:11. |
APA | Wang, Fu,Liao, Yuhong,&Hsu, Chang Samuel.(2025).On-line hydropyrolysis gas chromatography-mass spectrometry (HyPy-GC-MS) for kerogen-bound biomarkers.ORGANIC GEOCHEMISTRY,200,11. |
MLA | Wang, Fu,et al."On-line hydropyrolysis gas chromatography-mass spectrometry (HyPy-GC-MS) for kerogen-bound biomarkers".ORGANIC GEOCHEMISTRY 200(2025):11. |
入库方式: OAI收割
来源:广州地球化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。