Effect of Transcatheter Edge-to-Edge Repair on Left Ventricular Flow Features

文献类型:期刊论文

作者He XY(何心怡); Feng, Shuyi; Wu F(吴凡); Wang HP(王洪平); Wang SZ(王士召); Pan, Xiangbin
刊名CARDIOVASCULAR ENGINEERING AND TECHNOLOGY
出版日期2025-04-03
页码14
关键词Mitral regurgitation Left ventricular flow features MitraClip Hemodynamics TEER
ISSN号1869-408X
DOI10.1007/s13239-025-00781-2
通讯作者Wang, Hongping(hpwang@imech.ac.cn) ; Pan, Xiangbin(panxiangbin@fuwaihospital.org)
英文摘要Purpose This study aims to investigate the effects of transcatheter edge-to-edge repair (TEER) on left ventricular hemodynamics and its potential implications for patient health. Methods An in vitro experimental platform was designed to replicate the anatomical and functional characteristics of the left ventricle (LV). This platform integrates native porcine mitral and aortic valves with a patient-specific 3D-printed silicone LV. The LV hemodynamics after TEER is assessed using echocardiography and particle image velocimetry, focusing on critical indices such as vorticity, Reynolds shear stress (RSS), viscous shear stress (VSS), and energy dissipation rate (epsilon). Results TEER effectively reduces the degree of mitral regurgitation (MR); however, it significantly increases RSS, VSS, and epsilon due to the formation of numerous small-scale vortices in the LV. Conclusion These hemodynamic changes may lead to adverse left ventricular remodeling, red blood cell damage, and reduced cardiac pumping efficiency, which have to be taken into consideration to optimize the TEER procedure and improve patient outcomes.
分类号Q4
WOS关键词REGURGITATION ; MANAGEMENT ; PATTERNS
资助项目National Natural Science Foundation of China (NSFC) Basic Science Center Program for 'Multiscale Problems in Nonlinear Mechanics'[11988102] ; NSFC[12072348]
WOS研究方向Cardiovascular System & Cardiology ; Engineering
语种英语
WOS记录号WOS:001459055500001
资助机构National Natural Science Foundation of China (NSFC) Basic Science Center Program for 'Multiscale Problems in Nonlinear Mechanics' ; NSFC
其他责任者王洪平 ; Pan, Xiangbin
源URL[http://dspace.imech.ac.cn/handle/311007/100780]  
专题力学研究所_非线性力学国家重点实验室
推荐引用方式
GB/T 7714
He XY,Feng, Shuyi,Wu F,et al. Effect of Transcatheter Edge-to-Edge Repair on Left Ventricular Flow Features[J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY,2025:14.
APA 何心怡,Feng, Shuyi,吴凡,王洪平,王士召,&Pan, Xiangbin.(2025).Effect of Transcatheter Edge-to-Edge Repair on Left Ventricular Flow Features.CARDIOVASCULAR ENGINEERING AND TECHNOLOGY,14.
MLA 何心怡,et al."Effect of Transcatheter Edge-to-Edge Repair on Left Ventricular Flow Features".CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2025):14.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。