中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Biomechanical Effects of Partial Decortication on All-Suture and Conventional Suture Anchors in Different Bone Densities

文献类型:期刊论文

作者Zhu, Yiming1,3; Lian XC(连旭灿)2; Jiang, Chunyan1,3; Xiao C(肖驰)2; Zhao, Yang1,3
刊名JOVE-JOURNAL OF VISUALIZED EXPERIMENTS
出版日期2025-06-01
期号220页码:17
ISSN号1940-087X
DOI10.3791/68355
通讯作者Jiang, Chunyan(chunyanj@hotmail.com)
英文摘要While biomechanical testing has shown a correlation between decortication and anchor failure load, the effects of partial decortication on the biomechanical properties of all-suture anchors remain unclear. We aimed to evaluate the biomechanical effects of partial decortication on all-suture anchors and conventional suture anchors in Sawbones of varying densities. Suture anchors were tested in nondecorticated, partially decorticated, and completely decorticated Sawbones. Two types of all-suture anchors and one type of conventional anchor were evaluated. Two types of biphasic polyurethane foam were used to mimic normal bone: 0.32 g/cm3 density (20 pounds per cubic foot, pcf 20) and osteoporotic bone: 0.16 g/cm3 density (10 pounds per cubicfoot, pcf 10). Cyclicloadingswere applied, and peakdisplacementwas recorded. After cyclic loading tests, surviving anchors were subjected to pull-to-failure tests. The number of cycles, peak displacement, ultimate failure loads, and failure modes were determined. First, peak displacement was significantly influenced by bone density and anchor type: normal bone models exhibited lower peak displacement than osteoporotic models, and conventional screw-type anchors consistently demonstrated reduced peak displacement compared to all-suture anchors. In contrast, the extent of bone decortication-whether non-decorticated, partially decorticated, or completely decorticated-showed no significant effect on peak displacement. Second, in osteoporotic bone models (10 pounds per cubic foot), no significant difference in failure load was observed between the partially and non-decorticated groups, but both exhibited significantly higher values than the completely decorticated group.
分类号Q3
WOS关键词ROTATOR CUFF TEARS ; ARTHROSCOPIC REPAIR ; SHOULDER ; FEMURS
资助项目Beijing Jishuitan Research Funding[QN202509]
WOS研究方向Science & Technology - Other Topics
语种英语
WOS记录号WOS:001529575300033
资助机构Beijing Jishuitan Research Funding
其他责任者Jiang, Chunyan
源URL[http://dspace.imech.ac.cn/handle/311007/102068]  
专题力学研究所_非线性力学国家重点实验室
作者单位1.Beijing Res Inst Traumatol & Orthopaed, Beijing, Peoples R China;
2.Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech LNM, Beijing, Peoples R China
3.Capital Med Univ, Beijing Jishuitan Hosp, Sports Med Serv, Beijing, Peoples R China;
推荐引用方式
GB/T 7714
Zhu, Yiming,Lian XC,Jiang, Chunyan,et al. Biomechanical Effects of Partial Decortication on All-Suture and Conventional Suture Anchors in Different Bone Densities[J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS,2025(220):17.
APA Zhu, Yiming,连旭灿,Jiang, Chunyan,肖驰,&Zhao, Yang.(2025).Biomechanical Effects of Partial Decortication on All-Suture and Conventional Suture Anchors in Different Bone Densities.JOVE-JOURNAL OF VISUALIZED EXPERIMENTS(220),17.
MLA Zhu, Yiming,et al."Biomechanical Effects of Partial Decortication on All-Suture and Conventional Suture Anchors in Different Bone Densities".JOVE-JOURNAL OF VISUALIZED EXPERIMENTS .220(2025):17.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。