Effect of gas turbine intake air temperature regulating heat exchanger on combined cycle performance based on three-dimensional deformed tube

文献类型:期刊论文

作者Tu, Aimin1,2,3; Liu, Shijie1,2,3; Fu, Shiwan4; Hai, Chaofeng1,2,3; Zhu, Dongsheng1,2,3
刊名JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY
出版日期2023-07-31
页码16
关键词Part load condition Intake air temperature adjustment Waste heat recovery Heat exchange efficiency Gas steam combined cycle(GSCC) Gas turbine efficiency
ISSN号1388-6150
DOI10.1007/s10973-023-12377-w
通讯作者Liu, Shijie(liushijie@ms.giec.ac.cn)
英文摘要Aiming at the gas steam cycle system with partial load operation throughout the year, the influence of adding a gas turbine inlet temperature regulating heat exchanger on the energy efficiency of the combined cycle was analyzed based on the variation curve of the combined cycle partial load performance with inlet temperature of similar models provided in the literature. Taking the hot water temperature of the inlet temperature regulator designed for a certain gas steam cycle thermal power plant as the experimental testing conditions, and under the same inlet heater resistance limit conditions, the comprehensive performance of two types of gas-water heat exchangers using three-dimensional deformation tubes and composite steel aluminum fin tubes was tested and compared for analysis. Based on the performance characteristics and experimental calculation results of three-dimensional deformation tube heat exchangers, a new type of gas turbine inlet temperature regulator using three-dimensional deformation tubes was designed based on the local climate conditions and partial load operation characteristics of a thermal power plant. And the heating and cooling conditions of the gas turbine inlet temperature regulating device were discussed and analyzed for the typical operating conditions throughout the year. The conclusions obtained can provide reference for the selection of gas turbine inlet temperature regulators by power plant engineering technicians and the engineering application of this innovative gas turbine inlet temperature regulator.
WOS关键词TWISTED OVAL TUBE ; DESIGN PERFORMANCE ; PRESSURE-DROP ; RESISTANCE ; BUNDLE ; PLANT ; FLOW
资助项目National Key Ramp;D Program of China[2022YFB4202001] ; Special Cooperation Program of Jilin Province and Chinese Academy of Sciences[2022SYHZ0027] ; Science and Technology Commissioner of Guangdong Province[GDKTP2021047200]
WOS研究方向Thermodynamics ; Chemistry
语种英语
WOS记录号WOS:001040233900002
出版者SPRINGER
资助机构National Key Ramp;D Program of China ; Special Cooperation Program of Jilin Province and Chinese Academy of Sciences ; Science and Technology Commissioner of Guangdong Province
源URL[http://ir.giec.ac.cn/handle/344007/39156]  
专题中国科学院广州能源研究所
通讯作者Liu, Shijie
作者单位1.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China
2.Chinese Acad Sci, Key Lab Renewable Energy, Guangzhou 510640, Peoples R China
3.Guangdong Key Lab New & Renewable Energy Res & Dev, Guangzhou 510640, Peoples R China
4.Guangdong Yuehua Power Generat Co Ltd, Guangzhou 510731, Peoples R China
推荐引用方式
GB/T 7714
Tu, Aimin,Liu, Shijie,Fu, Shiwan,et al. Effect of gas turbine intake air temperature regulating heat exchanger on combined cycle performance based on three-dimensional deformed tube[J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY,2023:16.
APA Tu, Aimin,Liu, Shijie,Fu, Shiwan,Hai, Chaofeng,&Zhu, Dongsheng.(2023).Effect of gas turbine intake air temperature regulating heat exchanger on combined cycle performance based on three-dimensional deformed tube.JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY,16.