中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Simultaneous Detection of Nine Kinds of Estrogens in Water by Solid Phase Extraction Coupled with Gas Chromatography-Mass Spectrometry

文献类型:期刊论文

作者Liao Tao1; Wu Xiao-Cui1,2; Wang Shao-Hua1; Xie Song-Guang3; Xiong Guang-Quan1; Geng Sheng-Rong1; Li Xin1; Zu Xiao-Yan1; Hu Xiao-Bo2
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
出版日期2013-03-01
卷号41期号:3页码:422-426
关键词River water estrogens Solid phase extraction Gas chromatography-mass spectrometry
ISSN号0253-3820
通讯作者Hu, XB (reprint author), Huazhong Agr Univ, Coll Food Sci & Technol, Wuhan 430070, Peoples R China.
中文摘要Nine target compounds including estrone (E-1), 17 beta-estradiol (17 beta-E-2), estriol (E-3) 4-octylphenol(4-OP), 4-nonylphenol (4-NP), bisphenol A (BPA), diethylstilbestrol (DES), mestranol (EE3ME) and 17 alpha-ethinyl estradiol (17 alpha-EE2) were simultaneous detected by SPE-GC-MS. Extraction and derivatization conditions were optimized. The results showed that the average recoveries of the nine target estrogens extracted by Oasis HLB cartridges were higher than those by Satara cartridges, the optimal temperature of derivatization reaction was 75 degrees C and the optimal time of derivatization reaction was 90 min. The average recoveries of the nine target estrogens by Oasis HLB cartridges were 60.5% - 126.7%, and the relative standard deviations (RSD) were 0.8% - 11.1%, and the limits of detection (LOD) ranged from 1.08 ng/L to 8.60 ng/L. This method has been employed to detect the estrogens in environment samples from rivers.
英文摘要Nine target compounds including estrone (E-1), 17 beta-estradiol (17 beta-E-2), estriol (E-3) 4-octylphenol(4-OP), 4-nonylphenol (4-NP), bisphenol A (BPA), diethylstilbestrol (DES), mestranol (EE3ME) and 17 alpha-ethinyl estradiol (17 alpha-EE2) were simultaneous detected by SPE-GC-MS. Extraction and derivatization conditions were optimized. The results showed that the average recoveries of the nine target estrogens extracted by Oasis HLB cartridges were higher than those by Satara cartridges, the optimal temperature of derivatization reaction was 75 degrees C and the optimal time of derivatization reaction was 90 min. The average recoveries of the nine target estrogens by Oasis HLB cartridges were 60.5% - 126.7%, and the relative standard deviations (RSD) were 0.8% - 11.1%, and the limits of detection (LOD) ranged from 1.08 ng/L to 8.60 ng/L. This method has been employed to detect the estrogens in environment samples from rivers.
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Chemistry, Analytical
研究领域[WOS]Chemistry
关键词[WOS]LIQUID ; ENVIRONMENT ; STEROIDS ; SAMPLE ; MILK
收录类别SCI
语种英语
WOS记录号WOS:000318745100019
公开日期2013-10-31
源URL[http://ir.ihb.ac.cn/handle/342005/19289]  
专题水生生物研究所_淡水生态学研究中心_期刊论文
作者单位1.Hubei Acad Agr Sci, Inst Farm Prod Proc & Nucl Agr Technol, Hubei Engn Res Ctr Farm Prod Irradiat, Wuhan 430064, Peoples R China
2.Huazhong Agr Univ, Coll Food Sci & Technol, Wuhan 430070, Peoples R China
3.Chinese Acad Sci, Inst Hydrobiol, Wuhan 430072, Peoples R China
推荐引用方式
GB/T 7714
Liao Tao,Wu Xiao-Cui,Wang Shao-Hua,et al. Simultaneous Detection of Nine Kinds of Estrogens in Water by Solid Phase Extraction Coupled with Gas Chromatography-Mass Spectrometry[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2013,41(3):422-426.
APA Liao Tao.,Wu Xiao-Cui.,Wang Shao-Hua.,Xie Song-Guang.,Xiong Guang-Quan.,...&Hu Xiao-Bo.(2013).Simultaneous Detection of Nine Kinds of Estrogens in Water by Solid Phase Extraction Coupled with Gas Chromatography-Mass Spectrometry.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,41(3),422-426.
MLA Liao Tao,et al."Simultaneous Detection of Nine Kinds of Estrogens in Water by Solid Phase Extraction Coupled with Gas Chromatography-Mass Spectrometry".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 41.3(2013):422-426.

入库方式: OAI收割

来源:水生生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。