Performance Comparison of High-Temperature Heat Pumps with Different Vapor Refrigerant Injection Techniques
文献类型:期刊论文
| 作者 | Yang, Yuqiang1; Wang, Yu2,3; Xu, Zhaoyang2,3; Xie, Baojiang4; Hu, Yong4; Yu, Jiatao4; Chen, Yehong4; Zhang, Ting4; Lu, Zhenneng5; Gong, Yulie5 |
| 刊名 | PROCESSES
![]() |
| 出版日期 | 2024-03-01 |
| 卷号 | 12期号:3页码:13 |
| 关键词 | high-temperature heat pump vapor refrigerant injection technique sub-cooler flash tank industrial electrification |
| DOI | 10.3390/pr12030566 |
| 通讯作者 | Lu, Zhenneng(luzn@ms.giec.ac.cn) ; Gong, Yulie(gongyl@ms.giec.ac.cn) |
| 英文摘要 | In order to develop a highly efficient and stable high-temperature heat pump to realize high-efficient electrification in the industrial sector, performance of high-temperature heat pumps with a flash tank vapor injection and sub-cooler vapor injection are compared under different evaporation temperatures, condensation temperatures, compressor suction superheat degrees, subcooling degrees and compressor isentropic efficiencies. The results show that the COP, injection mass flow ratio and VHC of the FTVC are higher than those of the SVIC-0, SVIC-5, SVIC-10 and SVIC-20 under the same working conditions, while the discharge temperature of the FTVC is approximately equal to that of the SVIC-0 and lower than those of the SVIC-5, SVIC-10 and SVIC-20. When the evaporation temperature, the condensation temperature and injection pressure are 55 degrees C, 125 degrees C and 921.4 kPa, respectively, the system COP of the FTVC is 4.49, which is approximately 6.7%, 7.3%, 7.8% and 8.9% higher than those of the SVIC-0, SVIC-5, SVIC-10, and SVIC-20, respectively. |
| WOS关键词 | 2-PHASE ; LIQUID |
| 资助项目 | Science and Technology Projects of the State Grid Corporation of China |
| WOS研究方向 | Engineering |
| 语种 | 英语 |
| WOS记录号 | WOS:001192534100001 |
| 出版者 | MDPI |
| 资助机构 | Science and Technology Projects of the State Grid Corporation of China |
| 源URL | [http://ir.giec.ac.cn/handle/344007/41261] ![]() |
| 专题 | 中国科学院广州能源研究所 |
| 通讯作者 | Lu, Zhenneng; Gong, Yulie |
| 作者单位 | 1.State Grid Zhejiang Elect Power Co Ltd, Hangzhou 310007, Peoples R China 2.Wuhan Efficiency Evaluat Co Ltd, State Grid Elect Power Res Inst, Wuhan 430074, Peoples R China 3.Nari Grp Corp, State Grid Elect Power Res Inst, Nanjing 210000, Peoples R China 4.State Grid Zhejiang Elect Power Co Ltd, Shaoxing Power Supply Co, Shaoxing 312000, Peoples R China 5.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China |
| 推荐引用方式 GB/T 7714 | Yang, Yuqiang,Wang, Yu,Xu, Zhaoyang,et al. Performance Comparison of High-Temperature Heat Pumps with Different Vapor Refrigerant Injection Techniques[J]. PROCESSES,2024,12(3):13. |
| APA | Yang, Yuqiang.,Wang, Yu.,Xu, Zhaoyang.,Xie, Baojiang.,Hu, Yong.,...&Gong, Yulie.(2024).Performance Comparison of High-Temperature Heat Pumps with Different Vapor Refrigerant Injection Techniques.PROCESSES,12(3),13. |
| MLA | Yang, Yuqiang,et al."Performance Comparison of High-Temperature Heat Pumps with Different Vapor Refrigerant Injection Techniques".PROCESSES 12.3(2024):13. |
入库方式: OAI收割
来源:广州能源研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。