Analysis of the factors affecting heat transfer performance and prediction of heat transfer coefficient for MVR evaporator: A case study
文献类型:期刊论文
| 作者 | Yin, Hua1,2; Kong, Zhuwen3; Qian, Yuange3; Yang, Caiyun1,2 |
| 刊名 | CASE STUDIES IN THERMAL ENGINEERING
![]() |
| 出版日期 | 2024-03-01 |
| 卷号 | 55页码:20 |
| 关键词 | Heat transfer coefficient Evaporator Influencing factors Prediction SVR Physical models |
| ISSN号 | 2214-157X |
| DOI | 10.1016/j.csite.2024.104140 |
| 通讯作者 | Yin, Hua(yinhua@ms.giec.ac.cn) |
| 英文摘要 | The heat transfer coefficient of evaporation is one of the key factors affecting the design and management of evaporators. This paper presented an industrial case to investigate the influencing factors on the evaporator's heat transfer coefficient, as well as the interaction between the influencing factors. Besides, a comparison of accuracies was made between the heat transfer coefficients predicted by physical models and the support vector regression (SVR) model. The study results showed that due to the interaction between the influencing factors, changes in the heat transfer coefficient varied greatly from the laboratory results. The impact of other variables must be controlled for in industrial research. There were big errors between the results predicted by the early experimental or numerical models and the observed results. The root mean square error (RMSE) values and mean absolute percentage error (MAPE) values of the physical models were all greater than 150 and 5%, respectively, and their R2 values were all lower than 0.50. The data mining-based SVR predictions were more accurate than the predictions by physical models, with a maximum relative error of 5.38% and a minimum relative error of -5.60%. |
| WOS关键词 | LIQUID-FILMS ; ENERGY |
| WOS研究方向 | Thermodynamics |
| 语种 | 英语 |
| WOS记录号 | WOS:001208771700001 |
| 出版者 | ELSEVIER |
| 源URL | [http://ir.giec.ac.cn/handle/344007/41503] ![]() |
| 专题 | 中国科学院广州能源研究所 |
| 通讯作者 | Yin, Hua |
| 作者单位 | 1.Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy, 2 Nengyuan Rd, Guangzhou 510640, Peoples R China 2.Guangdong Key Lab New & Renewable Energy Res & Dev, 2 Nengyuan Rd, Guangzhou 510640, Peoples R China 3.Foshan Sanshui Dist Datang Sewage Treatment Co Ltd, 10 Xingtang Rd,Datang Ind Pk, Foshan 528143, Peoples R China |
| 推荐引用方式 GB/T 7714 | Yin, Hua,Kong, Zhuwen,Qian, Yuange,et al. Analysis of the factors affecting heat transfer performance and prediction of heat transfer coefficient for MVR evaporator: A case study[J]. CASE STUDIES IN THERMAL ENGINEERING,2024,55:20. |
| APA | Yin, Hua,Kong, Zhuwen,Qian, Yuange,&Yang, Caiyun.(2024).Analysis of the factors affecting heat transfer performance and prediction of heat transfer coefficient for MVR evaporator: A case study.CASE STUDIES IN THERMAL ENGINEERING,55,20. |
| MLA | Yin, Hua,et al."Analysis of the factors affecting heat transfer performance and prediction of heat transfer coefficient for MVR evaporator: A case study".CASE STUDIES IN THERMAL ENGINEERING 55(2024):20. |
入库方式: OAI收割
来源:广州能源研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。