英文摘要

Purpose Accurate localization of radioactive materials is critical to nuclear safety and nuclear security. A coded aperture imaging system provides a visualization solution. However, the correlation method has poor reconstruction performance for sources with low counts and for extended sources. Methods In this study, a Monte Carlo optimization-based MLEM algorithm (MC-MLEM) is proposed. The system matrix was obtained by accurate Monte Carlo simulation, so the physical effects such as mask penetration that affect the imaging process were taken into account in the MLEM algorithm. In the simulation process, the normalization of the system matrix was realized by controlling the source at different position of the source plane to have the same activity and emission angle. Results The experimental results showed that compared with the correlation method, the MC-MLEM algorithm could improve the signal-to-noise ratio and angular resolution and locate the source position quickly and accurately under low count conditions. Furthermore, the MC-MLEM algorithm could reconstruct the shape of the extended source and the expected activity ratio of cold-hot sources with large activity differences. Conclusion The MC-MLEM algorithm improved the imaging results and enhanced the reconstruction performance.

源URL[https://ir.ihep.ac.cn/handle/311005/304411]  
专题中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Yue YuXiaoli SunZhiming ZhangShuangquan LiuXiuzuo LiangDaowu LiLei ShuaiTingting HuLong Wei. Image reconstruction for the coded aperture system in nuclear safety and security using a Monte Carlo-based system matrix[J]. Radiation Detection Technology and Methods,2023,7(2).
APA Yue YuXiaoli SunZhiming ZhangShuangquan LiuXiuzuo LiangDaowu LiLei ShuaiTingting HuLong Wei.(2023).Image reconstruction for the coded aperture system in nuclear safety and security using a Monte Carlo-based system matrix.Radiation Detection Technology and Methods,7(2).
MLA Yue YuXiaoli SunZhiming ZhangShuangquan LiuXiuzuo LiangDaowu LiLei ShuaiTingting HuLong Wei."Image reconstruction for the coded aperture system in nuclear safety and security using a Monte Carlo-based system matrix".Radiation Detection Technology and Methods 7.2(2023).

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。