中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Study of the effects of source type and magnetic field on the spatial distribution of positron annihilation events in PET/MRI applications

文献类型:期刊论文

作者Zheng, WL; Cao, XZ; Li, C; Li, YX; Wang, BY; Han, ZJ; Liu, FY; Zhang, ZM; Wei, L
刊名EUROPEAN PHYSICAL JOURNAL PLUS
出版日期2019
卷号134期号:3
ISSN号2190-5444
DOI10.1140/epjp/i2019-12445-1
文献子类期刊
英文摘要.In this paper, we investigate the spatial distribution of positron annihilation events in PET//MRI systems. A spherical source ranging from 0mm to 10mm in radius was placed in water to represent the tumor region. The magnetic field strength was adjusted from 0T to 30T, and three positron nuclides, F-18 , C-11 , Ga-68 , were used. The positron annihilation distribution was compared with the nuclide distribution (to represent pathological tumor), and the differences in these distribution with and without the magnetic field were evaluated. The compression effect of magnetic field on positron distribution was also investigated. For C-11 and Ga-68 sources with radioactive source size (r(s)) of less than 4 mm and 6 mm, respectively, it was found that the critical radius (d of the sphere, which contains 90% annihilated positrons, was significantly larger than its original radioactive source size r(s). When the magnetic field was increased to 15T, it was found that the greatest compression occurred with a 2 mm Ga-68 source (which also exhibited the greatest contraction in volume V-1 although this was larger than the source volume V . Our proposed model of the volume source indicates that the positron distribution deviates greatly from the nuclide distribution for high-energy positron emitted in small source.
WOS关键词TRACK STRUCTURE SIMULATION ; RANGE CORRECTION ; TUMOR SIZE ; PET ; CANCER ; EMITTERS ; RESOLUTION ; SYSTEM ; IMPACT ; VOLUME
WOS研究方向Physics
语种英语
WOS记录号WOS:000460294900004
源URL[https://ir.ihep.ac.cn/handle/311005/304310]  
专题高能物理研究所_多学科研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Zheng, WL,Cao, XZ,Li, C,et al. Study of the effects of source type and magnetic field on the spatial distribution of positron annihilation events in PET/MRI applications[J]. EUROPEAN PHYSICAL JOURNAL PLUS,2019,134(3).
APA Zheng, WL.,Cao, XZ.,Li, C.,Li, YX.,Wang, BY.,...&Wei, L.(2019).Study of the effects of source type and magnetic field on the spatial distribution of positron annihilation events in PET/MRI applications.EUROPEAN PHYSICAL JOURNAL PLUS,134(3).
MLA Zheng, WL,et al."Study of the effects of source type and magnetic field on the spatial distribution of positron annihilation events in PET/MRI applications".EUROPEAN PHYSICAL JOURNAL PLUS 134.3(2019).

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。