中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A hybrid sodium/proton double-resonant transceiver array for 9.4T MRI

文献类型:期刊论文

作者Yan, Xinqiang; Shi, Lei; Wei, Long; Zhuo, Yan; Zhou, Xiaohong Joe; Xue, Rong
刊名2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications, IMWS-BIO 2013 - Proceedings
出版日期2013
DOI10.1109/IMWS-BIO.2013.6756178
文献子类Conference article (CA)
英文摘要

High field MRI makes it possible to obtain images of non-proton (X) nuclei due to its increased sensitivity. A double-resonant coil can provide both images of X nucleus and proton without the need to reposition the patient. Most double-resonant coils use lossy trap circuits to minimum interactions between X nucleus and H nucleus. In this study, we propose a hybrid sodium/proton double-tuned transceiver array for 9.4T MRI. The interactions were reduced by hybrid structure without using a lossy circuit. Compared with birdcage or TEM coils, the sensitivity of phased-array was better at the peripheral region of the phantom. For proton imaging at 9.4T, the microstrip transmission line (MTL) array structure was used as coil element for its good performance at ultra-high field. The RF circuit and 3-D EM co-simulation method was used to evaluate the performance of this hybrid double-resonant coil. A practical double-resonant coil with same parameters was built and its feasibility was validated through bench test. © 2013 IEEE.

ISBN号9781467360951
源URL[https://ir.ihep.ac.cn/handle/311005/304347]  
专题高能物理研究所_核技术应用研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Yan, Xinqiang,Shi, Lei,Wei, Long,et al. A hybrid sodium/proton double-resonant transceiver array for 9.4T MRI[J]. 2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications, IMWS-BIO 2013 - Proceedings,2013.
APA Yan, Xinqiang,Shi, Lei,Wei, Long,Zhuo, Yan,Zhou, Xiaohong Joe,&Xue, Rong.(2013).A hybrid sodium/proton double-resonant transceiver array for 9.4T MRI.2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications, IMWS-BIO 2013 - Proceedings.
MLA Yan, Xinqiang,et al."A hybrid sodium/proton double-resonant transceiver array for 9.4T MRI".2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications, IMWS-BIO 2013 - Proceedings (2013).

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。