Compact MPPC-based coded aperture imaging camera for dual-particle detection
文献类型:期刊论文
| 作者 | Jing Guo2,3; Xiaoyu Pang2,3; Jiale Cai3; Daowu Li2,3; Xiaoming Wang3; Xuanhou Hu3; Yue Yu2,3; Shuangquan Liu2,3; Xiuzuo Liang2,3; Yiwen Zhang3 |
| 刊名 | RADIATION DETECTION TECHNOLOGY AND METHODS
![]() |
| 出版日期 | 2021 |
| 卷号 | 5页码:61-70 |
| ISSN号 | 2509-9930 |
| DOI | 10.1007/s41605-020-00218-5 |
| 文献子类 | 期刊 |
| 英文摘要 | Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security. A compact coded aperture imaging (CAI) camera was designed to be sensitive to both gamma and neutron radiation based on plastic scintillators and multi-pixel photon counters (MPPC). Methods MPPCscoupling with the 13×13 pixelated plastic scintillators one-to-one were utilized to reduce the scale of the CAI system while maintaining good positional performance. The symmetric charge division (SCD) circuit was adopted to reduce the 169 signals output from the MPPC array to 26. Each waveform was collected and processed with four Domino Ring Sampler 4 (DRS4) chips and two 16-channel analog-to-digital converter (ADC) modules. As the pulse shapes of fast neutrons would be broadened after elastic scattering multiple times in the scintillators, the Anger-Logic method was applied to eliminate multiple elastic scattering events so that good pulse shape discrimination (PSD) performance can be achieved. Results Theimaginganddetectionabilityofthecamerawasevaluatedusingthe241Am-Be(5.9×105 n/s)neutronsourceand 137Cs(370MBq)gammasource.Thecameracanbeusedtodetectfastneutrons(0.5–10MeV)andgammarays(0.2–2.5MeV). Furthermore, it can implement efficient neutron/gamma PSD capabilities in the mixed-field environment. The figure of merit (FOM) of the camera calculated at 400keVee energy cut is 0.93. Conclusion A compact MPPC-based CAI camera was designed to detect and discriminate fast neutrons and gamma rays. Its good PSD performance was well suited to distinguish fast neutrons from gamma rays in a dual-particle environment. The portable design makes it promising for complex monitoring scenarios in nuclear security. |
| 语种 | 英语 |
| 源URL | [https://ir.ihep.ac.cn/handle/311005/304397] ![]() |
| 专题 | 高能物理研究所_核技术应用研究中心 |
| 作者单位 | 1.Jinan Laboratory of Applied Nuclear Science 2.School of Nuclear Science and Technology, University of Chinese Academy of Sciences 3.中国科学院高能物理研究所 |
| 推荐引用方式 GB/T 7714 | Jing Guo,Xiaoyu Pang,Jiale Cai,et al. Compact MPPC-based coded aperture imaging camera for dual-particle detection[J]. RADIATION DETECTION TECHNOLOGY AND METHODS,2021,5:61-70. |
| APA | Jing Guo.,Xiaoyu Pang.,Jiale Cai.,Daowu Li.,Xiaoming Wang.,...&Long Wei.(2021).Compact MPPC-based coded aperture imaging camera for dual-particle detection.RADIATION DETECTION TECHNOLOGY AND METHODS,5,61-70. |
| MLA | Jing Guo,et al."Compact MPPC-based coded aperture imaging camera for dual-particle detection".RADIATION DETECTION TECHNOLOGY AND METHODS 5(2021):61-70. |
入库方式: OAI收割
来源:高能物理研究所
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。

