Corrosion of Ti75 alloy in a 3.5 wt% NaCl solution containing different concentrations of Cu2+
文献类型:期刊论文
| 作者 | Li, D. H.1,2; Hu, H. X.1; Pan, H. D.2; Wang, Z. B.1; An, W. T.1,2; Zheng, Y. G.1 |
| 刊名 | CORROSION SCIENCE
![]() |
| 出版日期 | 2025-02-01 |
| 卷号 | 243页码:11 |
| 关键词 | Ti75 alloy Copper ion NaCl solution Passive films Electrochemical corrosion |
| ISSN号 | 0010-938X |
| DOI | 10.1016/j.corsci.2024.112567 |
| 通讯作者 | Hu, H. X.(hxhu@imr.ac.cn) ; Pan, H. D.(panhaodan@126.com) ; Wang, Z. B.(zbwang12s@imr.ac.cn) |
| 英文摘要 | The corrosion of Ti75 alloy was investigated in a neutral 3.5 wt% NaCl solution with five concentrations of Cu2+. Results demonstrated that the corrosion is the least in the control solution without Cu2+. However, a further increase in the Cu2+ concentration led to a decrease in corrosion due to the changes in passive film properties including its compositions and the carrier density. Moreover, both the corrosion potential and the diffusionlimited current density increase with the increasing Cu2+ concentration. Additionally, the effects of Cu2+ on both anodic and cathodic processes, as well as its role in the passive film's development, were analyzed. |
| 资助项目 | Natural Science Foundation of Liaoning Province of China[2023-MS-016] ; Youth Innovation Promotion Association CAS[2023200] ; China Association for Science and Technology[YESS20210013] |
| WOS研究方向 | Materials Science ; Metallurgy & Metallurgical Engineering |
| 语种 | 英语 |
| WOS记录号 | WOS:001365090100001 |
| 出版者 | PERGAMON-ELSEVIER SCIENCE LTD |
| 资助机构 | Natural Science Foundation of Liaoning Province of China ; Youth Innovation Promotion Association CAS ; China Association for Science and Technology |
| 源URL | ![]() |
| 专题 | 金属研究所_中国科学院金属研究所 |
| 通讯作者 | Hu, H. X.; Pan, H. D.; Wang, Z. B. |
| 作者单位 | 1.Chinese Acad Sci, CAS Key Lab Nucl Mat & Safety Assessment, Inst Met Res, Shenyang 110016, Peoples R China 2.Liaoning Petrochem Univ, Coll Petr Engn, Fushun 113301, Peoples R China |
| 推荐引用方式 GB/T 7714 | Li, D. H.,Hu, H. X.,Pan, H. D.,et al. Corrosion of Ti75 alloy in a 3.5 wt% NaCl solution containing different concentrations of Cu2+[J]. CORROSION SCIENCE,2025,243:11. |
| APA | Li, D. H.,Hu, H. X.,Pan, H. D.,Wang, Z. B.,An, W. T.,&Zheng, Y. G..(2025).Corrosion of Ti75 alloy in a 3.5 wt% NaCl solution containing different concentrations of Cu2+.CORROSION SCIENCE,243,11. |
| MLA | Li, D. H.,et al."Corrosion of Ti75 alloy in a 3.5 wt% NaCl solution containing different concentrations of Cu2+".CORROSION SCIENCE 243(2025):11. |
入库方式: OAI收割
来源:金属研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。