中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The influence of changing the sequence of concentration series on the 2D asynchronous spectroscopy generated by the asynchronous orthogonal sample design (AOSD) approach

文献类型:期刊论文

作者Li, Xiaopei1,2,3; Liu, Shaoxuan3; Chen, Jing3; Yue, Shijuan1,3; Liu, Cuige1; Wei, Yongju1; Huang, Kun2; Zhao, Ying4; Xu, Yizhuang3; Noda, Isao5
刊名VIBRATIONAL SPECTROSCOPY
出版日期2012-05-01
卷号60期号:si页码:212-216
关键词Intermolecular interaction Two-dimensional asynchronous spectroscopy AOSD Sequence Sensitivity
ISSN号0924-2031
通讯作者Wei, YJ
英文摘要The influence of the sequence of the concentration series is investigated on the 2D asynchronous spectra generated by the asynchronous orthogonal sample design (AOSD) approach. We prove that the requirement of the AOSD is also satisfied when the sequence of the concentration series changes, if the initial concentration series satisfies the requirement of the AOSD. Changing the sequence of concentration series produces the same absolute intensity of the 2D asynchronous spectra when only three solutions are used. However, different outcomes can be gained when four solutions are adopted. Studies on a real chemical system indicate that the sensitivity of the cross peak from asynchronous spectra can be improved significantly when the suitable sequence of concentration series is adopted. (C) 2011 Elsevier B.V. All rights reserved.
WOS标题词Science & Technology ; Physical Sciences ; Technology
类目[WOS]Chemistry, Analytical ; Chemistry, Physical ; Spectroscopy
研究领域[WOS]Chemistry ; Spectroscopy
关键词[WOS]INTERMOLECULAR INTERACTIONS ; INFRARED-SPECTROSCOPY ; ADENINE ; RAMAN
收录类别SCI
语种英语
WOS记录号WOS:000304685700039
公开日期2013-10-17
版本出版稿
源URL[http://ir.ipe.ac.cn/handle/122111/3789]  
专题过程工程研究所_湿法冶金清洁生产技术国家工程实验室
作者单位1.Hebei Normal Univ, Coll Chem & Mat Sci, Shijiazhuang 050016, Peoples R China
2.Chinese Acad Sci, Inst Proc Engn, Beijing 100190, Peoples R China
3.Peking Univ, Coll Chem & Mol Engn, State Key Lab Rare Earth Mat Chem & Applicat, Beijing Natl Lab Mol Sci, Beijing 100871, Peoples R China
4.Chinese Acad Sci, Inst Chem, Beijing 100190, Peoples R China
5.Procter & Gamble Co, W Chester, OH 45069 USA
推荐引用方式
GB/T 7714
Li, Xiaopei,Liu, Shaoxuan,Chen, Jing,et al. The influence of changing the sequence of concentration series on the 2D asynchronous spectroscopy generated by the asynchronous orthogonal sample design (AOSD) approach[J]. VIBRATIONAL SPECTROSCOPY,2012,60(si):212-216.
APA Li, Xiaopei.,Liu, Shaoxuan.,Chen, Jing.,Yue, Shijuan.,Liu, Cuige.,...&Wu, Jinguang.(2012).The influence of changing the sequence of concentration series on the 2D asynchronous spectroscopy generated by the asynchronous orthogonal sample design (AOSD) approach.VIBRATIONAL SPECTROSCOPY,60(si),212-216.
MLA Li, Xiaopei,et al."The influence of changing the sequence of concentration series on the 2D asynchronous spectroscopy generated by the asynchronous orthogonal sample design (AOSD) approach".VIBRATIONAL SPECTROSCOPY 60.si(2012):212-216.

入库方式: OAI收割

来源:过程工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。