Use of the glucose oxidase system for estimation of oxygen transfer rate in a solid-state bioreactor
文献类型:期刊论文
| 作者 | Zhao, H; Zhang, XY; Zhou, XH; Li, ZH |
| 刊名 | ENZYME AND MICROBIAL TECHNOLOGY
![]() |
| 出版日期 | 2002-06-04 |
| 卷号 | 30期号:7页码:843-846 |
| 关键词 | glucose oxidase system oxygen transfer rate periodic pressure oscillation solid-state bioreactor |
| ISSN号 | 0141-0229 |
| 其他题名 | Enzyme Microb. Technol. |
| 中文摘要 | The glucose oxidase system was adapted for estimation of the overall oxygen transfer rate in a periodic pressure oscillating, solid-state bioreactor. Enzyme concentration of 40 ml enzyme preparation L-1 was found adequate to give linear gluconic acid production and attain maximal oxygen absorption rates. At 4 atm and 30degreesC, the oxygen transfer rate reached 892 mmol kg(-1) initial dry matter h(-1) in this system, while only 121 mmol kg(-1) initial dry matter h(-1) was obtained in a conventional static tray bioreactor. (C) 2002 Elsevier Science Inc. All rights reserved. |
| 英文摘要 | The glucose oxidase system was adapted for estimation of the overall oxygen transfer rate in a periodic pressure oscillating, solid-state bioreactor. Enzyme concentration of 40 ml enzyme preparation L-1 was found adequate to give linear gluconic acid production and attain maximal oxygen absorption rates. At 4 atm and 30degreesC, the oxygen transfer rate reached 892 mmol kg(-1) initial dry matter h(-1) in this system, while only 121 mmol kg(-1) initial dry matter h(-1) was obtained in a conventional static tray bioreactor. (C) 2002 Elsevier Science Inc. All rights reserved. |
| WOS标题词 | Science & Technology ; Life Sciences & Biomedicine |
| 类目[WOS] | Biotechnology & Applied Microbiology |
| 研究领域[WOS] | Biotechnology & Applied Microbiology |
| 关键词[WOS] | FERMENTATION |
| 收录类别 | SCI |
| 原文出处 | |
| 语种 | 英语 |
| WOS记录号 | WOS:000175961300002 |
| 公开日期 | 2013-11-12 |
| 版本 | 出版稿 |
| 源URL | [http://ir.ipe.ac.cn/handle/122111/5689] ![]() |
| 专题 | 过程工程研究所_研究所(批量导入) |
| 作者单位 | Chinese Acad Sci, Inst Chem Met, State Key Lab Biochem Engn, Beijing 100080, Peoples R China |
| 推荐引用方式 GB/T 7714 | Zhao, H,Zhang, XY,Zhou, XH,et al. Use of the glucose oxidase system for estimation of oxygen transfer rate in a solid-state bioreactor[J]. ENZYME AND MICROBIAL TECHNOLOGY,2002,30(7):843-846. |
| APA | Zhao, H,Zhang, XY,Zhou, XH,&Li, ZH.(2002).Use of the glucose oxidase system for estimation of oxygen transfer rate in a solid-state bioreactor.ENZYME AND MICROBIAL TECHNOLOGY,30(7),843-846. |
| MLA | Zhao, H,et al."Use of the glucose oxidase system for estimation of oxygen transfer rate in a solid-state bioreactor".ENZYME AND MICROBIAL TECHNOLOGY 30.7(2002):843-846. |
入库方式: OAI收割
来源:过程工程研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。