Residence time distribution of liquid flow in a trickle bed evaluated using FFT deconvolution with coordinated smoothing
文献类型:期刊论文
作者 | Mao, ZS; Xiong, TY; Chen, JY |
刊名 | CHEMICAL ENGINEERING COMMUNICATIONS
![]() |
出版日期 | 1998-10-01 |
卷号 | 169期号:1页码:223-244 |
关键词 | residence time distribution deconvolution noise filtering trickle bed discrete Fast Fourier Transform |
ISSN号 | 0098-6445 |
其他题名 | Chem. Eng. Commun. |
中文摘要 | An approach of deconvolution by the Fast Fourier Transform (FFT) is applied to analyze the tracer response for evaluation of residence time distribution (RTD) from the raw data obtained in a double run of tracer experiments. A novel intuitive technique of coordinated smoothing in the frequency and time domains is tested for its accuracy and compared with the literature-reported method of regularization for measurement noise filtering. Tracer experiments were performed in 75 mm I. D. trickle bed packed with 2.7 mm glass beads, and RTD charts sampled in the trickling flow regime indicate that serious maldistribution of liquid trickling flow and hydrodynamic multiplicity exists even for a trickle bed with the ratio of height to diameter being up to 10. Using FFT deconvolution with coordinated smoothing to remove the interference originated outside the packed section seems to be effective and necessary for analysis and interpretation of tracer experiments. |
英文摘要 | An approach of deconvolution by the Fast Fourier Transform (FFT) is applied to analyze the tracer response for evaluation of residence time distribution (RTD) from the raw data obtained in a double run of tracer experiments. A novel intuitive technique of coordinated smoothing in the frequency and time domains is tested for its accuracy and compared with the literature-reported method of regularization for measurement noise filtering. Tracer experiments were performed in 75 mm I. D. trickle bed packed with 2.7 mm glass beads, and RTD charts sampled in the trickling flow regime indicate that serious maldistribution of liquid trickling flow and hydrodynamic multiplicity exists even for a trickle bed with the ratio of height to diameter being up to 10. Using FFT deconvolution with coordinated smoothing to remove the interference originated outside the packed section seems to be effective and necessary for analysis and interpretation of tracer experiments. |
WOS标题词 | Science & Technology ; Technology |
类目[WOS] | Engineering, Chemical |
研究领域[WOS] | Engineering |
收录类别 | SCI |
原文出处 | |
语种 | 英语 |
WOS记录号 | WOS:000165535400013 |
公开日期 | 2013-11-15 |
版本 | 出版稿 |
源URL | [http://ir.ipe.ac.cn/handle/122111/6052] ![]() |
专题 | 过程工程研究所_研究所(批量导入) |
作者单位 | 1.Acad Sinica, Inst Chem Met, Beijing 100080, Peoples R China 2.Acad Sinica, Inst Met Res, Shenyang 110015, Peoples R China |
推荐引用方式 GB/T 7714 | Mao, ZS,Xiong, TY,Chen, JY. Residence time distribution of liquid flow in a trickle bed evaluated using FFT deconvolution with coordinated smoothing[J]. CHEMICAL ENGINEERING COMMUNICATIONS,1998,169(1):223-244. |
APA | Mao, ZS,Xiong, TY,&Chen, JY.(1998).Residence time distribution of liquid flow in a trickle bed evaluated using FFT deconvolution with coordinated smoothing.CHEMICAL ENGINEERING COMMUNICATIONS,169(1),223-244. |
MLA | Mao, ZS,et al."Residence time distribution of liquid flow in a trickle bed evaluated using FFT deconvolution with coordinated smoothing".CHEMICAL ENGINEERING COMMUNICATIONS 169.1(1998):223-244. |
入库方式: OAI收割
来源:过程工程研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。