Synchrotrons radiation stability measurement and improvement
文献类型:期刊论文
作者 | Tang, SW(唐思巍) ; Yin, CX(殷重先) ; Liu, DK(刘德康) |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES
![]() |
出版日期 | 2012 |
卷号 | 23期号:1 |
ISSN号 | 1001-8042 |
英文摘要 | In the 3rd generation synchrotron light source, beside the orbit, air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement. In the condition of implementation of orbit feedback system at SSRF, the measured position stability of photon beam in synchrotrons radiation measurement station was presented in this paper. And then the improvement methods of position stability of photon beam were discussed. Finally the measured result was shown when the designed feedback system is implemented to improve the position stability of photon beam. |
语种 | 英语 |
WOS记录号 | WOS:000303971000002 |
公开日期 | 2013-12-05 |
源URL | [http://ir.sinap.ac.cn/handle/331007/13304] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
推荐引用方式 GB/T 7714 | Tang, SW,Yin, CX,Liu, DK. Synchrotrons radiation stability measurement and improvement[J]. NUCLEAR SCIENCE AND TECHNIQUES,2012,23(1). |
APA | Tang, SW,Yin, CX,&Liu, DK.(2012).Synchrotrons radiation stability measurement and improvement.NUCLEAR SCIENCE AND TECHNIQUES,23(1). |
MLA | Tang, SW,et al."Synchrotrons radiation stability measurement and improvement".NUCLEAR SCIENCE AND TECHNIQUES 23.1(2012). |
入库方式: OAI收割
来源:上海应用物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。