Analysis of Artemisinin in 1-Ethyl-3-Methylimidazolium Bromide-Water System by Reversed Phase High Performance Liquid Chromatography
文献类型:期刊论文
| 作者 | Xia Yu-Jie1,2; Zeng Jian-Li1,2; Zhao Bing1; Wang Yu-Chuo1 |
| 刊名 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
![]() |
| 出版日期 | 2009-04-01 |
| 卷号 | 37期号:4页码:573-576 |
| 关键词 | Artemisinin ionic liquid 1-ethyl-3-methylimidazolium bromide reversed phase high performance liquid chromatography |
| ISSN号 | 0253-3820 |
| 通讯作者 | Zhao, B |
| 英文摘要 | A reversed phase high performance liquid chromatographic(RP-HPLC) method was developed for the quantitative analysis of artemisinin in a new ionic liquid system of 1-ethyl-3-methylimidazolium bromide-water. The determination was carried out on a C(18) column (250 mm x 4. 6 mm, 5 mu m) at room temperature (25 +/- 1) degrees C. Methanol-0.01 mol/l. HAc-NaAc (pH 5. 9) 60:40, V/V) was used as mobile phase at a flow rate of 0. 5 mL/min and detection wavelength was set at 260 nm. The calibration curve was a good linear relationship of artemisinin concentration in the range of 5 - 30 mg/L. The corresponding regression equation was y = 2. 20326 x 10(7)x - 30928. 7, r = 0. 9990. The recovery of artemisinin was 100. 2% and relative standard deviation was 0. 4%. |
| WOS标题词 | Science & Technology ; Physical Sciences |
| 类目[WOS] | Chemistry, Analytical |
| 研究领域[WOS] | Chemistry |
| 关键词[WOS] | IONIC LIQUIDS ; ANTIMALARIAL-DRUG ; SEPARATION ; EXTRACTION |
| 收录类别 | SCI |
| 语种 | 英语 |
| WOS记录号 | WOS:000265617900019 |
| 公开日期 | 2013-12-09 |
| 版本 | 出版稿 |
| 源URL | [http://ir.ipe.ac.cn/handle/122111/6693] ![]() |
| 专题 | 过程工程研究所_生化工程国家重点实验室 |
| 作者单位 | 1.Chinese Acad Sci, Natl Key Lab Biochem Engn, Inst Proc Engn, Beijing 100190, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
| 推荐引用方式 GB/T 7714 | Xia Yu-Jie,Zeng Jian-Li,Zhao Bing,et al. Analysis of Artemisinin in 1-Ethyl-3-Methylimidazolium Bromide-Water System by Reversed Phase High Performance Liquid Chromatography[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2009,37(4):573-576. |
| APA | Xia Yu-Jie,Zeng Jian-Li,Zhao Bing,&Wang Yu-Chuo.(2009).Analysis of Artemisinin in 1-Ethyl-3-Methylimidazolium Bromide-Water System by Reversed Phase High Performance Liquid Chromatography.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,37(4),573-576. |
| MLA | Xia Yu-Jie,et al."Analysis of Artemisinin in 1-Ethyl-3-Methylimidazolium Bromide-Water System by Reversed Phase High Performance Liquid Chromatography".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 37.4(2009):573-576. |
入库方式: OAI收割
来源:过程工程研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。

