Humidity-Induced Spectral Shift in a Cross-Dispersion Echelle Spectrometer and Its Theoretical Investigation
文献类型:期刊论文
作者 | Liu Ke-ling1; Huang Mao2; Gary, Hieftje M.3 |
刊名 | SPECTROSCOPY AND SPECTRAL ANALYSIS
![]() |
出版日期 | 2010-09-01 |
卷号 | 30期号:9页码:2555-2559 |
关键词 | Emission spectrometry Position shift of a spectral line Spectral-shift equation |
ISSN号 | 1000-0593 |
其他题名 | Spectrosc. Spectr. Anal. |
中文摘要 | The relationship between ambient relative humidity H and the position shift of a spectral line was investigated both experimentally and theoretically. An echelle-based ICP emission spectrometer equipped with a CID detector was used for experimental verification of the derived model. The shift of a spectral line is quantitatively described by two defined spectral shift functions: Delta lambda(x) (x, lambda, H) (in the x direction of the CID detector) and Delta lambda(y) (y, lambda, H) (in the y direction of the CID detector). Experimental results indicate that Delta lambda(x) (x, lambda, H) does not change with a variation in ambient relative humidity, but Delta lambda(y) (y, lambda, H) does. A spectral shift equation, i. e. an empirical second-order polynomial equation, can be used to describe the relationship between Delta lambda(y) (y, lambda, H) and H. Based on the classical dipole model, classical mechanics and electrodynamics the empirical spectral-shift equation involving Delta lambda(y) (y, lambda, H) and H was theoretically deduced. The theoretical result is in good agreement with the experimental findings. The theoretical result's indicate that the coefficients of the empirical spectral-shift equation are related to the basic physical parameters of materials and the geometric configuration of the echelle CID ICP-AES, and also provide physical meaning to the coefficients of the empirical shift equation obtained experimentally. |
英文摘要 | The relationship between ambient relative humidity H and the position shift of a spectral line was investigated both experimentally and theoretically. An echelle-based ICP emission spectrometer equipped with a CID detector was used for experimental verification of the derived model. The shift of a spectral line is quantitatively described by two defined spectral shift functions: Delta lambda(x) (x, lambda, H) (in the x direction of the CID detector) and Delta lambda(y) (y, lambda, H) (in the y direction of the CID detector). Experimental results indicate that Delta lambda(x) (x, lambda, H) does not change with a variation in ambient relative humidity, but Delta lambda(y) (y, lambda, H) does. A spectral shift equation, i. e. an empirical second-order polynomial equation, can be used to describe the relationship between Delta lambda(y) (y, lambda, H) and H. Based on the classical dipole model, classical mechanics and electrodynamics the empirical spectral-shift equation involving Delta lambda(y) (y, lambda, H) and H was theoretically deduced. The theoretical result is in good agreement with the experimental findings. The theoretical result's indicate that the coefficients of the empirical spectral-shift equation are related to the basic physical parameters of materials and the geometric configuration of the echelle CID ICP-AES, and also provide physical meaning to the coefficients of the empirical shift equation obtained experimentally. |
WOS标题词 | Science & Technology ; Technology |
类目[WOS] | Spectroscopy |
研究领域[WOS] | Spectroscopy |
收录类别 | SCI |
原文出处 | |
语种 | 英语 |
WOS记录号 | WOS:000281661000057 |
公开日期 | 2013-11-28 |
版本 | 出版稿 |
源URL | [http://ir.ipe.ac.cn/handle/122111/6366] ![]() |
专题 | 过程工程研究所_研究所(批量导入) |
作者单位 | 1.Chinese Acad Sci, Inst Proc Engn, Beijing 100190, Peoples R China 2.Lib Chinese Acad Sci, Beijing 100190, Peoples R China 3.Indiana Univ, Dept Chem, Bloomington, IN 47405 USA |
推荐引用方式 GB/T 7714 | Liu Ke-ling,Huang Mao,Gary, Hieftje M.. Humidity-Induced Spectral Shift in a Cross-Dispersion Echelle Spectrometer and Its Theoretical Investigation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2010,30(9):2555-2559. |
APA | Liu Ke-ling,Huang Mao,&Gary, Hieftje M..(2010).Humidity-Induced Spectral Shift in a Cross-Dispersion Echelle Spectrometer and Its Theoretical Investigation.SPECTROSCOPY AND SPECTRAL ANALYSIS,30(9),2555-2559. |
MLA | Liu Ke-ling,et al."Humidity-Induced Spectral Shift in a Cross-Dispersion Echelle Spectrometer and Its Theoretical Investigation".SPECTROSCOPY AND SPECTRAL ANALYSIS 30.9(2010):2555-2559. |
入库方式: OAI收割
来源:过程工程研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。