中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Highly porous magnetite/graphene nanocomposites for a solid-state electrochemiluminescence sensor on paper-based chips

文献类型:期刊论文

作者Xu YH ; Lv ZZ ; Xia Y ; Han YC ; Lou BH ; Wang EK
刊名analytical and bioanalytical chemistry
出版日期2013
卷号405期号:11页码:3549-3558
关键词CHEMILUMINESCENCE OXIDATION FILMS ECL
ISSN号1618-2642
通讯作者wang ek
中文摘要graphene-nanosheet-based highly porous magnetite nanocomposites (gn-hpmns) have been prepared using a simple solvothermal method and used as an immobilization matrix for the fabrication of a solid-state electrochemiluminescence (ecl) sensor on paper-based chips. highly porous fe3o4 nanocrystal clusters were coated with acrylate and wrapped tightly on the skeleton of graphene nanosheets. the structures and sizes of the gn-hpmns could be tuned by varying the proportions of the solvents ethylene glycol and diethylene glycol. then, the relatively highly porous ones with an average diameter of about 65 nm were combined with nafion to form composite films on an electrode surface for immobilization of ru(bpy)(3)(2+) (bpy is 2,2'-bipyridine). because of their porosity, negatively charged surface, and cooperative characteristics of magnetic nanomaterials and graphene, under an external magnetic field, the gn-hpmns ensured effective immobilization, excellent electron transfer, and long-term stability of ru(bpy)(3)(2+) in the composite film. the sensor developed exhibited excellent reproducibility with a relative standard deviation of 0.65 % for 30 continuous cycles. it was found to be much more favorable for detecting compounds containing tertiary amino groups and dnas with guanine and adenine. a detection limit (signal-to-noise ratio of 3) of 5.0 nm was obtained for tripropylamine. as an application example, 0.5 nm single-nucleotide mismatch could be detected. this was the first attempt to introduce magnetic nanomaterials and an external magnetic field into paper-based chips. the sensor developed has the advantages of high sensitivity, good stability, and wide potential applicability as well as simplicity, low cost, and good disposability.
收录类别SCI收录期刊论文
语种英语
WOS记录号WOS:000317643100010
公开日期2014-04-16
源URL[http://ir.ciac.jl.cn/handle/322003/49934]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Xu YH,Lv ZZ,Xia Y,et al. Highly porous magnetite/graphene nanocomposites for a solid-state electrochemiluminescence sensor on paper-based chips[J]. analytical and bioanalytical chemistry,2013,405(11):3549-3558.
APA Xu YH,Lv ZZ,Xia Y,Han YC,Lou BH,&Wang EK.(2013).Highly porous magnetite/graphene nanocomposites for a solid-state electrochemiluminescence sensor on paper-based chips.analytical and bioanalytical chemistry,405(11),3549-3558.
MLA Xu YH,et al."Highly porous magnetite/graphene nanocomposites for a solid-state electrochemiluminescence sensor on paper-based chips".analytical and bioanalytical chemistry 405.11(2013):3549-3558.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。