Joule heating effects on reservoir-based dielectrophoresis
文献类型:期刊论文
作者 | Kale A; Patel S; Qian SZ; Hu GQ(胡国庆)![]() |
刊名 | Electrophoresis
![]() |
出版日期 | 2014-03 |
卷号 | 35期号:5页码:721-727 |
通讯作者邮箱 | xcxuan@clemson.edu |
ISSN号 | 0173-0835 |
产权排序 | [Kale, Akshay; Patel, Saurin; Xuan, Xiangchun] Clemson Univ, Dept Mech Engn, Clemson, SC 29634 USA; [Qian, Shizhi] Old Dominion Univ, Inst Micro Nanotechnol, Norfolk, VA USA; [Hu, Guoqing] Chinese Acad Sci, Inst Mech, LNM, Beijing 100080, Peoples R China |
通讯作者 | Xuan, XC (reprint author), Clemson Univ, Dept Mech Engn, Clemson, SC 29634 USA. |
合作状况 | 国际 |
中文摘要 | Reservoir-based dielectrophoresis (rDEP) is a recently developed technique that exploits the inherent electric field gradients at a reservoir-microchannel junction to focus, trap, and sort particles. However, the locally amplified electric field at the junction is likely to induce significant Joule heating effects that are not considered in previous studies. This work investigates experimentally and numerically these effects on particle transport and control in rDEP processes in PDMS/PDMS microchips. It is found that Joule heating effects can reduce rDEP focusing considerably and may even disable rDEP trapping. This is caused by the fluid temperature rise at the reservoir-microchannel junction, which significantly increases the local particle velocity due to fluid flow and particle electrophoresis while has a weak impact on the particle velocity due to rDEP. The numerical predictions of particle stream width and electric current, which are the respective indicators of rDEP manipulation and fluid temperature, are demonstrated to both match the experimental measurements with a good accuracy. |
学科主题 | Biochemistry & Molecular Biology; Chemistry |
分类号 | 二类/Q1 |
收录类别 | SCI |
资助信息 | This work is partially supported by NSF under grant CBET-0853873 (Xuan), NRF of Korea under grant 2011-0014246 (Qian), and by NSFC under grant 11272321 (Hu). The Open Fund support from LNM (Xuan and Hu) is also gratefully acknowledged. |
原文出处 | http://dx.doi.org/10.1002/elps.201300343 |
语种 | 英语 |
WOS记录号 | WOS:000332342200014 |
公开日期 | 2014-05-09 |
源URL | [http://dspace.imech.ac.cn/handle/311007/48777] ![]() |
专题 | 力学研究所_非线性力学国家重点实验室 |
推荐引用方式 GB/T 7714 | Kale A,Patel S,Qian SZ,et al. Joule heating effects on reservoir-based dielectrophoresis[J]. Electrophoresis,2014,35(5):721-727. |
APA | Kale A,Patel S,Qian SZ,Hu GQ,&Xuan XC.(2014).Joule heating effects on reservoir-based dielectrophoresis.Electrophoresis,35(5),721-727. |
MLA | Kale A,et al."Joule heating effects on reservoir-based dielectrophoresis".Electrophoresis 35.5(2014):721-727. |
入库方式: OAI收割