DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY
文献类型:期刊论文
作者 | Sun, Aide1; Xu, Qingcai1; Xu, Shujian1; Shangguan, Xuehui1; Shen, Hongyuan1; Sun, Jing2,3 |
刊名 | analytical letters |
出版日期 | 2013-11-02 |
卷号 | 46期号:16页码:2610-2619 |
ISSN号 | 0003-2719 |
关键词 | Boron Determination Headspace liquid phase micro-sublimation Inductively coupled plasma optical emission spectrometry Water |
通讯作者 | sun, j (reprint author), chinese acad sci, northwest inst plateau biol, 23 xinning rd, xining 810008, peoples r china. |
中文摘要 | trace boron in water and plant samples was preconcentrated by a novel headspace liquid phase micro-sublimation method, followed by determination by inductively coupled plasma optical emission spectroscopy. sodium hydroxide solution was used as the absorption solvent during the preconcentration step. the type and volume of absorption solvent, absorption time and temperature, and ph of the absorption solution and sample solution were optimized for the extraction. the linear range was from 0.1 to 80 mu g/ml, with a relative standard deviation of 7.4%. the limit of detection based on a signal-to-noise ratio of three was 0.008 mu g/ml. under the optimized conditions, real water samples and plant samples were analyzed. the results showed this method can be applied for the determination of boron in environmental samples. |
英文摘要 | trace boron in water and plant samples was preconcentrated by a novel headspace liquid phase micro-sublimation method, followed by determination by inductively coupled plasma optical emission spectroscopy. sodium hydroxide solution was used as the absorption solvent during the preconcentration step. the type and volume of absorption solvent, absorption time and temperature, and ph of the absorption solution and sample solution were optimized for the extraction. the linear range was from 0.1 to 80 mu g/ml, with a relative standard deviation of 7.4%. the limit of detection based on a signal-to-noise ratio of three was 0.008 mu g/ml. under the optimized conditions, real water samples and plant samples were analyzed. the results showed this method can be applied for the determination of boron in environmental samples. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | solvent microextraction ; mass-spectrometry ; ion-exchange ; separation ; water |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000325049300010 |
公开日期 | 2014-05-09 |
源URL | [http://ir.nwipb.ac.cn/handle/363003/3901] |
专题 | 西北高原生物研究所_中国科学院西北高原生物研究所 |
作者单位 | 1.Linyi Univ, Coll Resource & Environm, Shandong Prov Key Lab Soil Conservat & Environm P, Linyi, Peoples R China 2.Chinese Acad Sci, Northwest Inst Plateau Biol, Key Lab Adaptat & Evolut Plateau Biota, Xining 810008, Peoples R China 3.Chinese Acad Sci, Northwest Inst Plateau Biol, Qinghai Key Lab Qinghai Tibet Plateau Biol Resour, Xining 810008, Peoples R China |
推荐引用方式 GB/T 7714 | Sun, Aide,Xu, Qingcai,Xu, Shujian,et al. DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY[J]. analytical letters,2013,46(16):2610-2619. |
APA | Sun, Aide,Xu, Qingcai,Xu, Shujian,Shangguan, Xuehui,Shen, Hongyuan,&Sun, Jing.(2013).DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY.analytical letters,46(16),2610-2619. |
MLA | Sun, Aide,et al."DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY".analytical letters 46.16(2013):2610-2619. |
入库方式: OAI收割
来源:西北高原生物研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。