中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY

文献类型:期刊论文

作者Sun, Aide1; Xu, Qingcai1; Xu, Shujian1; Shangguan, Xuehui1; Shen, Hongyuan1; Sun, Jing2,3
刊名analytical letters
出版日期2013-11-02
卷号46期号:16页码:2610-2619
ISSN号0003-2719
关键词Boron Determination Headspace liquid phase micro-sublimation Inductively coupled plasma optical emission spectrometry Water
通讯作者sun, j (reprint author), chinese acad sci, northwest inst plateau biol, 23 xinning rd, xining 810008, peoples r china.
中文摘要trace boron in water and plant samples was preconcentrated by a novel headspace liquid phase micro-sublimation method, followed by determination by inductively coupled plasma optical emission spectroscopy. sodium hydroxide solution was used as the absorption solvent during the preconcentration step. the type and volume of absorption solvent, absorption time and temperature, and ph of the absorption solution and sample solution were optimized for the extraction. the linear range was from 0.1 to 80 mu g/ml, with a relative standard deviation of 7.4%. the limit of detection based on a signal-to-noise ratio of three was 0.008 mu g/ml. under the optimized conditions, real water samples and plant samples were analyzed. the results showed this method can be applied for the determination of boron in environmental samples.
英文摘要trace boron in water and plant samples was preconcentrated by a novel headspace liquid phase micro-sublimation method, followed by determination by inductively coupled plasma optical emission spectroscopy. sodium hydroxide solution was used as the absorption solvent during the preconcentration step. the type and volume of absorption solvent, absorption time and temperature, and ph of the absorption solution and sample solution were optimized for the extraction. the linear range was from 0.1 to 80 mu g/ml, with a relative standard deviation of 7.4%. the limit of detection based on a signal-to-noise ratio of three was 0.008 mu g/ml. under the optimized conditions, real water samples and plant samples were analyzed. the results showed this method can be applied for the determination of boron in environmental samples.
WOS标题词science & technology ; physical sciences
类目[WOS]chemistry, analytical
研究领域[WOS]chemistry
关键词[WOS]solvent microextraction ; mass-spectrometry ; ion-exchange ; separation ; water
收录类别SCI
语种英语
WOS记录号WOS:000325049300010
公开日期2014-05-09
源URL[http://ir.nwipb.ac.cn/handle/363003/3901]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
作者单位1.Linyi Univ, Coll Resource & Environm, Shandong Prov Key Lab Soil Conservat & Environm P, Linyi, Peoples R China
2.Chinese Acad Sci, Northwest Inst Plateau Biol, Key Lab Adaptat & Evolut Plateau Biota, Xining 810008, Peoples R China
3.Chinese Acad Sci, Northwest Inst Plateau Biol, Qinghai Key Lab Qinghai Tibet Plateau Biol Resour, Xining 810008, Peoples R China
推荐引用方式
GB/T 7714
Sun, Aide,Xu, Qingcai,Xu, Shujian,et al. DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY[J]. analytical letters,2013,46(16):2610-2619.
APA Sun, Aide,Xu, Qingcai,Xu, Shujian,Shangguan, Xuehui,Shen, Hongyuan,&Sun, Jing.(2013).DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY.analytical letters,46(16),2610-2619.
MLA Sun, Aide,et al."DETERMINATION OF BORON USING HEADSPACE LIQUID PHASE MICRO-SUBLIMATION COUPLED WITH INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY".analytical letters 46.16(2013):2610-2619.

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。