热门
综合孔径微波辐射计信道误差分析与标定
文献类型:期刊论文
作者 | 刘浩 ; 吴季 ; 吴琼 |
刊名 | 电子学报
![]() |
出版日期 | 2005 |
卷号 | 33期号:3页码:402-406 |
关键词 | 综合孔径微波辐射计 信道不平衡 串扰 互耦 定标 |
ISSN号 | 0372-2112 |
其他题名 | Analysis and Calibration of the Channels Error of Synthetic Aperture Radiometer |
通讯作者 | 北京8701信箱 |
中文摘要 | 本文首先建立了综合孔径微波辐射计的信道模型,在此基础上分析了信道的幅度相位不平衡以及信道间串扰对反演亮温的影响,并给出了系统仿真结果.本文还提出了一种新的系统定标方案,与传统定标方法相比,该方法可以非常方便的获取高精度的系统调制G矩阵用于亮温反演. |
英文摘要 | Theoretical channels model of synthetic aperture radiometer are presented.Based on this model ,how amplitude imbalance ,phase imbalance and mutual coupling between the different receiving channels effect brightness temperature retrieving is analyzed.The computer simulation results are also presented ,in which the cause of the along-track streaks usually appeared in the retrieved image is identified.In addition,a new system calibration approach is introduced to solve this problem: using digital I2Q vector modulators to simulate the point source in the antenna range ,we can get more accurate GMatrix to retrieve the brightness temperature image.This new approach,as compared with the existing calibration methods ,is especially suitable for in situ use. |
学科主题 | 微波遥感 |
收录类别 | CSCD |
资助信息 | 国家高技术研究发展计划(863 计划)课题 |
语种 | 中文 |
CSCD记录号 | CSCD:1962436 |
源URL | [http://ir.cssar.ac.cn/handle/122/2041] ![]() |
专题 | 国家空间科学中心_微波遥感部 |
推荐引用方式 GB/T 7714 | 刘浩,吴季,吴琼. 综合孔径微波辐射计信道误差分析与标定[J]. 电子学报,2005,33(3):402-406. |