Experimental investigation of mouse kidney aging with SR PCI technology
文献类型:期刊论文
作者 | Yifeng, P. ; Zehua, Z. ; Guohao, D. ; Tiqiao, X.(肖体乔) ; Hongjie, X.(徐洪杰) ; Peiping, Z. |
刊名 | JOURNAL OF INSTRUMENTATION
![]() |
出版日期 | 2013 |
卷号 | 8 |
ISSN号 | 1748-0221 |
英文摘要 | Objective. Basing on the coherence character of the Synchrotron radiation (SR), the mouse kidney study is performed using the propagation-based phase-contrast imaging (PCI) technology which as one approach of the phase contrasts imaging (PCI). The aim of this paper was to visualize the kidney at different ages and evaluate the latent value of aging mechanism with SR phase contrast imaging technology. Methods. The experiments were performed at the BL13W1 line of the SSRF (the Shanghai synchrotron radiation facility), the samples were soaked in 10% formalin solution, the mouse kidneys at different ages were imaged on the shelf in the propagation-based phase-contrast imaging setup and captured with CCD. The captured images were analyzed and compared. Results. When the distance is 50 cm between the samples and imaging plate, good contrast and high resolution were obtained in the propagation-based phase-contrast imaging (PCI), as such renal capsule revealed well, and the resolution reach to 30 micron; there is significant difference in the shape and vessels structures among the mouse kidneys at different age. Conclusion. The PCI is good for the applying of main light element organization imaging, the difference in shape and vessels structure between the young and old mouse kidney maybe indicated at some extent with the propagation-based phase-contrast imaging technology. |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000324017400004 |
公开日期 | 2014-06-13 |
源URL | [http://ir.sinap.ac.cn/handle/331007/13743] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
推荐引用方式 GB/T 7714 | Yifeng, P.,Zehua, Z.,Guohao, D.,et al. Experimental investigation of mouse kidney aging with SR PCI technology[J]. JOURNAL OF INSTRUMENTATION,2013,8. |
APA | Yifeng, P.,Zehua, Z.,Guohao, D.,Tiqiao, X.,Hongjie, X.,&Peiping, Z..(2013).Experimental investigation of mouse kidney aging with SR PCI technology.JOURNAL OF INSTRUMENTATION,8. |
MLA | Yifeng, P.,et al."Experimental investigation of mouse kidney aging with SR PCI technology".JOURNAL OF INSTRUMENTATION 8(2013). |
入库方式: OAI收割
来源:上海应用物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。