中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Validation of techniques to mitigate copper surface contamination in CUORE

文献类型:期刊论文

作者Alessandria, F. ; Ardito, R. ; Artusa, D. R. ; Avignone, F. T., III ; Azzolini, O. ; Balata, M. ; Banks, T. I. ; Bari, G. ; Beeman, J. ; Bellini, F. ; Bersani, A. ; Biassoni, M. ; Bloxham, T. ; Brofferio, C. ; Bucci, C. ; Cai, X. Z. ; Canonica, L. ; Capelli, S. ; Carbone, L. ; Cardani, L. ; Carrettoni, M. ; Casali, N. ; Chott, N. ; Clemenza, M. ; Cosmelli, C. ; Cremonesi, O. ; Creswick, R. J. ; Dafinei, I. ; Dally, A. ; Datskov, V. ; De Biasi, A. ; Deninno, M. M. ; Di Domizio, S. ; di Vacri, M. L. ; Ejzak, L. ; Faccini, R. ; Fang, D. Q. ; Farach, H. A. ; Ferri, E. ; Ferroni, F. ; Fiorini, E. ; Franceschi, M. A. ; Freedman, S. J. ; Fujikawa, B. K. ; Giachero, A. ; Gironi, L. ; Giuliani, A. ; Goett, J. ; Goodsell, A. ; Gorla, P. ; Gotti, C. ; Guardincerri, E. ; Gutierrez, T. D. ; Haller, E. E. ; Han, K. ; Heeger, K. M. ; Huang, H. Z. ; Kadel, R. ; Kazkaz, K. ; Keppel, G. ; Kogler, L. ; Kolomensky, Yu. G. ; Lenz, D. ; Li, Y. L. ; Ligi, C. ; Liu, X. ; Ma, Y. G. ; Maiano, C. ; Maino, M. ; Martinez, M. ; Maruyama, R. H. ; Mei, Y. ; Moggi, N. ; Morganti, S. ; Napolitano, T. ; Newman, S. ; Nisi, S. ; Nones, C. ; Norman, E. B. ; Nucciotti, A. ; Orio, F. ; Orlandi, D. ; Ouellet, J. L. ; Pallavicini, M. ; Palmieri, V. ; Pattavina, L. ; Pavan, M. ; Pedretti, M. ; Pessina, G. ; Pirro, S. ; Previtali, E. ; Rampazzo, V. ; Reil, R. ; Rimondi, F. ; Rosenfeld, C. ; Rusconi, C. ; Sangiorgio, S. ; Scielzo, N. D. ; Sisti, M. ; Smith, A. R. ; Sparks, L. ; Stivanello, F. ; Taffarello, L. ; Tenconi, M. ; Tian, W. D. ; Tomei, C. ; Trentalange, S. ; Ventura, G. ; Vignati, M. ; Wang, B. S. ; Wang, H. W. ; Whitten, C. A., Jr. ; Wise, T. ; Woodcraft, A. ; Zanotti, L. ; Zarra, C. ; Zhu, B. X. ; Zucchelli, S.
刊名ASTROPARTICLE PHYSICS
出版日期2013
卷号45页码:CONCATENATE(Sheet1!I388,-Sheet1!J388)
ISSN号0927-6505
英文摘要In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10(-7)- 10(-8) Bq/cm(2) are achieved for U-238 and Th-232. If these levels are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit on the number of background counts in the region of interest is 0.02-0.03 counts/keV/kg/y depending on the adopted mitigation technique. (C) 2013 Elsevier B.V. All rights reserved.
收录类别SCI
语种英语
WOS记录号WOS:000324010600002
公开日期2014-06-13
源URL[http://ir.sinap.ac.cn/handle/331007/13982]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Alessandria, F.,Ardito, R.,Artusa, D. R.,et al. Validation of techniques to mitigate copper surface contamination in CUORE[J]. ASTROPARTICLE PHYSICS,2013,45:CONCATENATE(Sheet1!I388,-Sheet1!J388).
APA Alessandria, F..,Ardito, R..,Artusa, D. R..,Avignone, F. T., III.,Azzolini, O..,...&Zucchelli, S..(2013).Validation of techniques to mitigate copper surface contamination in CUORE.ASTROPARTICLE PHYSICS,45,CONCATENATE(Sheet1!I388,-Sheet1!J388).
MLA Alessandria, F.,et al."Validation of techniques to mitigate copper surface contamination in CUORE".ASTROPARTICLE PHYSICS 45(2013):CONCATENATE(Sheet1!I388,-Sheet1!J388).

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。