顺序注射亚硝酸盐检测仪的研制及应用

文献类型:期刊论文

作者吕颖 ; 陈令新 ; 孙西艳 ; 付龙文 ; 冯巍巍
刊名环境化学
出版日期2013
卷号32期号:10页码:1950-1955
关键词顺序注射 亚硝酸盐 分光光度法 在线监测 水质分析.
ISSN号0254-6108
其他题名Development of a sequential injection analyzer and its application in the determination of nitrite in environmental water samples
产权排序中国科学院烟台海岸带研究所;中国科学院海岸带环境过程与生态修复重点实验室;中国科学院大学;
通讯作者陈令新 E-mail:lxchen@yic.ac.cn
中文摘要基于顺序注射分析技术与格里斯试剂比色法的原理,研制了一台全自动检测环境水样中亚硝酸盐的仪器,并成功应用于实际水样的检测.该仪器经优化调试后的物理条件为管内径0.8 mm、定量环长度90 cm、反应时间3.5 min;格里斯化学试剂的改进结果为磷酸体积分数为11%,磺胺(SA)浓度为45 g·L-1,N-(1-萘基)-乙二胺盐酸盐(NED 2HCl)浓度为50 mg·L-1.在最优化条件下,亚硝酸盐的线性检测范围是10—1000μg·L-1,检出限为4.14μg·L-1,相对标准偏差1.2%,实际水样的加标回收率在105.4%—122.1%之间.由于本仪器操作便捷,灵敏度高,抗干扰能力强,因此适...
英文摘要An automatic instrument based on sequential injection analysis technique and Griess reagent colorimetric method was developed and applied to the determination of nitrite in environmental water samples. The instrument's physical parameters were optimized as follow: the tuner diameter of pipe, 0. 8 mm; length of sample loop, 90 cm; reaction time, 3.5 min. The optimized composition of the colorimetric neagents were that the volume fraction of phosphoric acid was 11%, and concentrations of sulfonamides (SA) and N-(1-naphthyl)-ethylenediamine hydrochloride salt (NED 2HC1) were 45 g· L-1 and 50 mg · L-1, respectively. Under the optimized conditions, a linear rang of 10-1000 μg·L-1 , detection limit of 4.14 μg·L-1 , relative standard deviation of 1.2% and recovery rate of 105.4%-122. 1% were achieved. The instrument is simple, automatic, reliable and therefore applicable for on-line and real-time determination of nitrite in complex water samples. Keywords: sequential injection analysis, nitrite, spectrophotometry, online monitoring, water quality analysis.
学科主题环境化学
收录类别CSCD
资助信息中国科学院“百人计划”项目资助
语种中文
CSCD记录号CSCD:4976435
公开日期2014-07-06
源URL[http://ir.yic.ac.cn/handle/133337/6817]  
专题烟台海岸带研究所_中科院海岸带环境过程与生态修复重点实验室
推荐引用方式
GB/T 7714
吕颖,陈令新,孙西艳,等. 顺序注射亚硝酸盐检测仪的研制及应用[J]. 环境化学,2013,32(10):1950-1955.
APA 吕颖,陈令新,孙西艳,付龙文,&冯巍巍.(2013).顺序注射亚硝酸盐检测仪的研制及应用.环境化学,32(10),1950-1955.
MLA 吕颖,et al."顺序注射亚硝酸盐检测仪的研制及应用".环境化学 32.10(2013):1950-1955.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。