Impact of reflection on the fluence rate distribution in a UV reactor with various inner walls as measured using a micro-fluorescent silica detector

文献类型:期刊论文

作者Li, Mengkai ; Qiang, Zhimin ; Bolton, James R. ; Ben, Weiwei
刊名Engineering; Environmental Sciences & Ecology; Water Resources
出版日期2012
卷号46期号:11页码:3595-3602
关键词UV reactor Inner-wall reflection Fluence rate distribution In-situ measurement Micro-fluorescent silica detector
ISSN号0043-1354
中文摘要An assessment of the impact of ultraviolet (UV) reflection from inner walls is important for the accuracy of model predictions of fluence rate (FR) distribution and for the improvement of reactor efficiency. In this study, the FR distribution in an annular UV reactor with inner walls of various reflectances was measured in-situ by using a 360 degrees response micro-fluorescent silica detector. The tests were performed in water with various transmittances ranging from 65% to 99% and with inner reactor walls composed of quartz/aluminum foil, quartz/stainless steel, or quartz/black cloth, whose reflection coefficients were determined to be 80.5%, 26.1% and 11.1%, respectively. The results demonstrate that an inner wall with a high reflection coefficient can lead to a marked increase in the weighted average FRs, thus greatly improving the reactor efficiency. Furthermore, the presently used FR distribution models could have an error of up to 35% for commonly used stainless steel walls as a result of the influence of inner-wall reflection. Finally, it was found that the uniformity of the FR distribution is strongly dependent on the diffuse reflection property of the inner wall, which could lead to a better fluence delivery distribution in the UV reactor. This work has potential application to increase the accuracy of model predictions as well as optimize the design of high-efficiency UV reactors. (C) 2012 Elsevier Ltd. All rights reserved.
WOS记录号WOS:000304850600016
公开日期2014-11-28
源URL[http://ir.rcees.ac.cn/handle/311016/8140]  
专题生态环境研究中心_环境水质学国家重点实验室
推荐引用方式
GB/T 7714
Li, Mengkai,Qiang, Zhimin,Bolton, James R.,et al. Impact of reflection on the fluence rate distribution in a UV reactor with various inner walls as measured using a micro-fluorescent silica detector[J]. Engineering; Environmental Sciences & Ecology; Water Resources,2012,46(11):3595-3602.
APA Li, Mengkai,Qiang, Zhimin,Bolton, James R.,&Ben, Weiwei.(2012).Impact of reflection on the fluence rate distribution in a UV reactor with various inner walls as measured using a micro-fluorescent silica detector.Engineering; Environmental Sciences & Ecology; Water Resources,46(11),3595-3602.
MLA Li, Mengkai,et al."Impact of reflection on the fluence rate distribution in a UV reactor with various inner walls as measured using a micro-fluorescent silica detector".Engineering; Environmental Sciences & Ecology; Water Resources 46.11(2012):3595-3602.