Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip
文献类型:期刊论文
作者 | Wang CL; Li JQ; Li HW; Jin G(靳刚); Wang ZH(王战会); Meng YH(孟永宏); Xiu RJ |
刊名 | Artificial Cells Blood Substitutes and Biotechnology |
出版日期 | 2009 |
卷号 | 37期号:4页码:183-186 |
通讯作者邮箱 | wangchlcams@yahoo.com.cn |
ISSN号 | 1073-1199 |
关键词 | Soluble Tie-2 Acute Myocardial Infarction Elisa Optical Protein-Chip Imaging Ellipsometry Imaging Ellipsometry Tyrosine Kinase Tek |
通讯作者 | Wang CL |
合作状况 | 国内 |
中文摘要 | The Tie-2 receptor has been shown to play a role in angiogenesis in atherosclerosis. The conventional method assaying the level of soluble Tie-2 (sTie-2) was ELISA. However, this method has some disadvantages. The aims of this research are to establish a more simple detection method, the optical protein-chip based on imaging ellipsomtry (OPC-IE) applying to Tie-2 assay. The sTie-2 biosensor surface on silicon wafer was prepared first, and then serum levels of sTie-2 in 38 patients with AMI were measured on admission (day 1), day 2, day 3 and day 7 after onset of chest pain and 41 healthy controls by ELISA and OPC-IE in parallel. Median level of sTie-2 increased significantly in the AMI patients when compared with the controls. Statistics showed there was a significant correlation in sTie-2 results between the two methods (r=0.923, P0.01). The result of this study showed that the level of sTie-2 increased in AMI, and OPC-IE assay was a fast, reliable, and convenient technique to measure sTie-2 in serum. |
类目[WOS] | Biotechnology & Applied Microbiology ; Engineering, Biomedical ; Materials Science, Biomaterials |
研究领域[WOS] | Biotechnology & Applied Microbiology ; Engineering ; Materials Science |
关键词[WOS] | IMAGING ELLIPSOMETRY ; TYROSINE KINASE ; TEK |
收录类别 | SCI |
原文出处 | http://dx.doi.org/10.1080/10731190903043416 |
语种 | 英语 |
WOS记录号 | WOS:000267835500007 |
公开日期 | 2009-08-03 ; 2009-10-09 |
源URL | [http://dspace.imech.ac.cn/handle/311007/26690] |
专题 | 力学研究所_国家微重力实验室 |
推荐引用方式 GB/T 7714 | Wang CL,Li JQ,Li HW,et al. Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip[J]. Artificial Cells Blood Substitutes and Biotechnology,2009,37(4):183-186. |
APA | Wang CL.,Li JQ.,Li HW.,Jin G.,Wang ZH.,...&Xiu RJ.(2009).Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip.Artificial Cells Blood Substitutes and Biotechnology,37(4),183-186. |
MLA | Wang CL,et al."Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip".Artificial Cells Blood Substitutes and Biotechnology 37.4(2009):183-186. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。