Spectral stray light effect on high-temperature measurements using a near-infrared multi-wavelength pyrometer
文献类型:期刊论文
作者 | Fu TR; Duan MG; Liu JF; Li T(李腾)![]() |
刊名 | INFRARED PHYSICS & TECHNOLOGY
![]() |
出版日期 | 2014-11 |
卷号 | 67页码:590-595 |
通讯作者邮箱 | trfu@mail.tsinghua.edu.cn |
关键词 | Temperature Pyrometer Multi-wavelength Spectral stray light |
ISSN号 | 1350-4495 |
产权排序 | [Fu, Tairan; Duan, Minghao; Liu, Jiangfan] Tsinghua Univ, Dept Thermal Engn, Beijing Key Lab Utilizat & Reduct Technol CO2, Key Lab Thermal Sci & Power Engn,Minist Educ, Beijing 100084, Peoples R China; [Li, Teng] Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China |
通讯作者 | Fu, TR (reprint author), Tsinghua Univ, Dept Thermal Engn, Beijing Key Lab Utilizat & Reduct Technol CO2, Key Lab Thermal Sci & Power Engn,Minist Educ, Beijing 100084, Peoples R China. |
中文摘要 | The spectral stray light is a major, non-negligible error source affecting spectral intensity measurements for optical instruments. The purpose of this study is to investigate the effects of spectral stray light on high-temperature measurements using a near-infrared (1.0-1.65 mu m) multi-wavelength pyrometer. The spectral stray light corrections were measured for the multi-wavelength pyrometer using a pulsed tunable laser for wavelengths from 0.41 mu m to 2.63 mu m. A matrix correction method was then used for the spectral stray light for the multi-wavelength pyrometer. The spectral response characteristics of the pyrometer were calibrated using a standard high-temperature blackbody source. The experimental results show that the spectral response characteristics are approximately identical for different calibration temperatures when the spectral stray light correction is used. The corrections for the spectral stray light significantly improve the accuracy of the multi-wavelength pyrometer at a blackbody calibration temperature which gives a simplified accurate calibration procedure, unlike the temperature calibrations for general optical pyrometers. Temperature measurement tests using a multi-wavelength pyrometer for standard high-temperature source further verified the measurement accuracy of the calibrated pyrometer which also illustrates the necessity of the spectral stray light corrections for the complex optical pyrometer and the applicability of the multi-wavelength algorithm. (C) 2014 Elsevier B.V. All rights reserved. |
分类号 | 二类 |
收录类别 | SCI ; EI |
资助信息 | This work was supported by the National Natural Science Foundation of China (No. 51176100), the Science Fund for Creative Research Groups of the National Natural Science Foundation of China (No. 51321002), the National Basic Research Program of China (No. 2011CB706900), the Program for New Century Excellent Talents in University (NCET-13-0315) and the Beijing Higher Education Young Elite Teacher Project (YETP0091). We thank Prof. D.M. Christopher for editing the English. |
原文出处 | http://dx.doi.org/10.1016/j.infrared.2014.10.004 |
语种 | 英语 |
WOS记录号 | WOS:000346549700088 |
公开日期 | 2015-01-23 |
源URL | [http://dspace.imech.ac.cn/handle/311007/49485] ![]() |
专题 | 力学研究所_高温气体动力学国家重点实验室 |
推荐引用方式 GB/T 7714 | Fu TR,Duan MG,Liu JF,et al. Spectral stray light effect on high-temperature measurements using a near-infrared multi-wavelength pyrometer[J]. INFRARED PHYSICS & TECHNOLOGY,2014,67:590-595. |
APA | Fu TR,Duan MG,Liu JF,&李腾.(2014).Spectral stray light effect on high-temperature measurements using a near-infrared multi-wavelength pyrometer.INFRARED PHYSICS & TECHNOLOGY,67,590-595. |
MLA | Fu TR,et al."Spectral stray light effect on high-temperature measurements using a near-infrared multi-wavelength pyrometer".INFRARED PHYSICS & TECHNOLOGY 67(2014):590-595. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。