NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging
文献类型:期刊论文
作者 | Li S(李森)![]() ![]() |
刊名 | Applied Energy
![]() |
出版日期 | 2009 |
卷号 | 86期号:9页码:1797-1803 |
通讯作者邮箱 | lisen@imech.ac.cn |
ISSN号 | 0306-2619 |
通讯作者 | 李森 |
合作状况 | 国内 |
中文摘要 | Full-scale experiments were performed on a 300 MWe utility boiler retrofitted with air staging. In order to improve boiler thermal efficiency and to reduce NOx emission, the influencing factors including the overall excessive air ratio, the secondary air distribution pattern, the damper openings of CCOFA and SOFA, and pulverized coal fineness were investigated. Through comprehensive combustion adjustment, NOx emission decreased 182 ppm (NOx reduction efficiency was 44%), and boiler heat efficiency merely decreased 0.21%. After combustion improvement, high efficiency and low NOx emission was achieved in the utility coal-fired boiler retrofitted with air staging, and the unburned carbon in ash can maintain at a desired level where the utilization of fly-ash as byproducts was not influenced. |
学科主题 | 电磁流体力学和等离子体动力学 |
类目[WOS] | Energy & Fuels ; Engineering, Chemical |
研究领域[WOS] | Energy & Fuels ; Engineering |
关键词[WOS] | STAGED COMBUSTION ; NITROGEN CONVERSION ; COAL |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000265735300052 |
公开日期 | 2009-10-14 |
源URL | [http://dspace.imech.ac.cn/handle/311007/26770] ![]() |
专题 | 力学研究所_等离子体与燃烧中心(2009-2011) |
推荐引用方式 GB/T 7714 | Li S,Xu TM,Hui SE,et al. NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging[J]. Applied Energy,2009,86(9):1797-1803. |
APA | 李森,徐通模,Hui SE,&魏小林.(2009).NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging.Applied Energy,86(9),1797-1803. |
MLA | 李森,et al."NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging".Applied Energy 86.9(2009):1797-1803. |
入库方式: OAI收割
来源:力学研究所