Efficient Interface for Online Coupling of Capillary Electrophoresis with Inductively Coupled Plasma-Mass Spectrometry and Its Application in Simultaneous Speciation Analysis of Arsenic and Selenium
文献类型:期刊论文
作者 | Liu, Lihong ; Yun, Zhaojun ; He, Bin ; Jiang, Guibin |
刊名 | ANALYTICAL CHEMISTRY
![]() |
出版日期 | 2014 |
卷号 | 86期号:16页码:8167-8175 |
ISSN号 | 0003-2700 |
中文摘要 | A simple and highly efficient online system coupling of capillary electrophoresis to inductively coupled plasma-mass spectrometry (CE-ICP-MS) for simultaneous separation and determination of arsenic and selenium compounds was developed. CE was coupled to an ICP-MS system by a sprayer with a novel direct-injection high-efficiency nebulizer (DIHEN) chamber as the interface. By using this interface, six arsenic species, including arsenite (As(III), arsenate (As(V)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) and five selenium species (such as sodium selenite (Se(IV)), sodium selenate (Se(VI)), selenocysteine (SeCys), selenomethionine (SeMet), and Se-methylselenocysteine (MeSeCys)) were baseline-separated and determined in a single run within 9 min under the optimized conditions. Minimum dead volume, low and steady sheath flow liquid, high nebulization efficiency, and high sample transport efficiency were obtained by using this interface. Detection limits were in the range of 0.11-0.37 mu g L-1 for the six arsenic compounds (determined as As-75 at m/z 75) and 1.33-2.31 mu g L-1 for the five selenium species (determined as Se-82 at m/z 82). Repeatability expressed as the relative standard deviations (RSD, n = 6) of both migration time and peak area were better than 2.68% for arsenic compounds and 3.28% for selenium compounds, respectively. The proposed method had been successfully applied for the determination of arsenic and selenium species in the certified reference materials DORM-3, water, urine, and fish samples. |
WOS记录号 | WOS:000340701500022 |
公开日期 | 2015-03-24 |
源URL | [http://ir.rcees.ac.cn/handle/311016/9356] ![]() |
专题 | 生态环境研究中心_环境化学与生态毒理学国家重点实验室 |
推荐引用方式 GB/T 7714 | Liu, Lihong,Yun, Zhaojun,He, Bin,et al. Efficient Interface for Online Coupling of Capillary Electrophoresis with Inductively Coupled Plasma-Mass Spectrometry and Its Application in Simultaneous Speciation Analysis of Arsenic and Selenium[J]. ANALYTICAL CHEMISTRY,2014,86(16):8167-8175. |
APA | Liu, Lihong,Yun, Zhaojun,He, Bin,&Jiang, Guibin.(2014).Efficient Interface for Online Coupling of Capillary Electrophoresis with Inductively Coupled Plasma-Mass Spectrometry and Its Application in Simultaneous Speciation Analysis of Arsenic and Selenium.ANALYTICAL CHEMISTRY,86(16),8167-8175. |
MLA | Liu, Lihong,et al."Efficient Interface for Online Coupling of Capillary Electrophoresis with Inductively Coupled Plasma-Mass Spectrometry and Its Application in Simultaneous Speciation Analysis of Arsenic and Selenium".ANALYTICAL CHEMISTRY 86.16(2014):8167-8175. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。