Imaging and measuring methods for coating layer thickness of TRISO-coated fuel particles with high accuracy
文献类型:期刊论文
作者 | Yang, Min1; Zhang, Jianhai2; Song, Sung-Jin2; Li, Xingdong3; Meng, Fanyong4; Kang, To2; Liu, Wenli3; Wei, Dongbo1 |
刊名 | NDT & E INTERNATIONAL
![]() |
出版日期 | 2013-04-01 |
卷号 | 55期号:0页码:82-89 |
关键词 | TRISO-coated fuel particle Thickness measurement X-ray phase contrast imaging Image denoising Edge detection |
英文摘要 | TRISO-coated fuel particles are the main innovation of high-temperature gas-cooled reactors (HTGRs), which effectively improve the safety of reactors for higher stability at high temperature. The structure of the typical ball-type TRISO-coated fuel particle comprises a nuclear fuel particle as a kernel and four outer coating layers. These layers play an important role as a barrier against fission product diffusion, and ensuring the integrity of the particles. As one of the key quality parameters of TRISO particles, the coating layer thickness must be measured accurately by non-destructive means. Conventional X-ray radiography, which is based on attenuation contrast, is a non-destructive alternative to measure the coating layer thickness. However, the attenuation contrast is determined by the density difference of the material. For the weakly absorbing material of coating layers composed of carbon and silicon, the variations of the thickness and density of different coating layers are not large enough to realize accurate thickness measurement. In order to obtain ideal images with enhanced boundaries, we applied in-line phase contrast imaging (PCI) based on a micro-focus X-ray source for the inspection of fuel particles. The method is more powerful for acquiring radiographs with sharper edges than conventional X-ray radiography. An improved NL-means method was adopted to decrease the image noise while preserving the detailed information effectively. Finally, based on the denoised DR image with sharper boundaries obtained by PCI, edge detection with sub-pixel accuracy and thickness measurement results are shown. (C) 2013 Elsevier Ltd. All rights reserved. |
WOS标题词 | Science & Technology ; Technology |
类目[WOS] | Materials Science, Characterization & Testing |
研究领域[WOS] | Materials Science |
关键词[WOS] | MICRO-CT ; CONTRAST ; RECONSTRUCTION ; RESOLUTION ; DETECTOR |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000316374000012 |
公开日期 | 2015-05-27 |
源URL | [http://ir.ipe.ac.cn/handle/122111/13737] ![]() |
专题 | 过程工程研究所_研究所(批量导入) |
作者单位 | 1.Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Beijing 100191, Peoples R China 2.Sungkyunkwan Univ, Sch Mech Engn, Suwon 440746, South Korea 3.Natl Inst Metrol, Beijing 100013, Peoples R China 4.Chinese Acad Sci, Inst Proc Engn, State Key Lab Multiphase Complex Syst, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Yang, Min,Zhang, Jianhai,Song, Sung-Jin,et al. Imaging and measuring methods for coating layer thickness of TRISO-coated fuel particles with high accuracy[J]. NDT & E INTERNATIONAL,2013,55(0):82-89. |
APA | Yang, Min.,Zhang, Jianhai.,Song, Sung-Jin.,Li, Xingdong.,Meng, Fanyong.,...&Wei, Dongbo.(2013).Imaging and measuring methods for coating layer thickness of TRISO-coated fuel particles with high accuracy.NDT & E INTERNATIONAL,55(0),82-89. |
MLA | Yang, Min,et al."Imaging and measuring methods for coating layer thickness of TRISO-coated fuel particles with high accuracy".NDT & E INTERNATIONAL 55.0(2013):82-89. |
入库方式: OAI收割
来源:过程工程研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。