"Ready-to-use" hollow nanofiber membrane-based glucose testing strips

文献类型:期刊论文

作者Ji, Xiaoyuan1; Su, Zhiguo1,2; Wang, Ping1,3,4; Ma, Guanghui1; Zhang, Songping1,2
刊名ANALYST
出版日期2014-12-21
卷号139期号:24页码:6467-6473
关键词ELECTROCHEMICAL BIOSENSORS ENZYME IMMOBILIZATION COMPOSITE NANOFIBERS GOLD NANOPARTICLES CARBON NANOFIBER OXIDASE ELECTRODE NANOCOMPOSITE NANOTUBE POLYMER
ISSN号0003-2654
通讯作者Zhang, SP (reprint author), Chinese Acad Sci, Inst Proc Engn, Natl Key Lab Biochem Engn, Beijing 100190, Peoples R China.
英文摘要A novel "ready-to-use" glucose test strip based on a polyurethane hollow nanofiber membrane was fabricated through facile co-axial electrospinning. By utilizing glucose oxidase and horseradish peroxidase in the core-phase solution, and a chromogenic agent either in the core solution (in which case 2,2'-azinobis-(3-ethylbenzthiazoline-6-sulphonate) (ABTS) was used) or in the shell-phase solution (in which case o-dianisidine was used) for co-axial electrospinning, in situ co-encapsulation of the two enzymes within the hollow nano-chamber and incorporation of chromogenic agents either inside the nano-chamber or in the shell of the hollow nanofibers was realized. Such unique "all-in-one" feature enabled the prepared hollow nanofiber membrane-based test strips to be applied either as colorimetric sensors in solution or as an optical biosensor operated in the "dip-and-read" mode. When used as a colorimetric biosensor in solution, the test strip with o-dianisidine as chromogenic agent shows an excellent linear response range between 0.01 mM to 20 mM and a high apparent lumped activity recovery of 62.1% as compared to the reaction rate of the free bi-enzyme system. While the activity recovery of the test strip with ABTS as chromogenic agent is only 18.0%, and the test strip is found to be unstable due to spontaneous-oxidation of the ABTS. The o-dianisidine test strip was also applied as an optical biosensor, visible rufous color was quickly developed on the surface of the membrane upon dropping 10 mu L of glucose sample, and an excellent correlation between differential diffusive reflectance of the test strip at 440 nm and glucose concentration was obtained in the range of 0.5-50 mM. The test strips also exhibited excellent long-term storage stability with a half-life at 25 degrees C as long as four months.
WOS标题词Science & Technology ; Physical Sciences
学科主题Chemistry
类目[WOS]Chemistry, Analytical
研究领域[WOS]Chemistry
关键词[WOS]ELECTROCHEMICAL BIOSENSORS ; ENZYME IMMOBILIZATION ; COMPOSITE NANOFIBERS ; GOLD NANOPARTICLES ; CARBON NANOFIBER ; OXIDASE ; ELECTRODE ; NANOCOMPOSITE ; NANOTUBE ; POLYMER
收录类别SCI
语种英语
WOS记录号WOS:000345265300020
源URL[http://ir.ipe.ac.cn/handle/122111/15243]  
专题过程工程研究所_研究所(批量导入)
作者单位1.Chinese Acad Sci, Inst Proc Engn, Natl Key Lab Biochem Engn, Beijing 100190, Peoples R China
2.Collaborat Innovat Ctr Chem Sci & Engn Tianjin, Tianjin 300072, Peoples R China
3.Univ Minnesota, Dept Bioprod & Biosyst Engn, St Paul, MN 55108 USA
4.Univ Minnesota, Inst Biotechnol, St Paul, MN 55108 USA
推荐引用方式
GB/T 7714
Ji, Xiaoyuan,Su, Zhiguo,Wang, Ping,et al. "Ready-to-use" hollow nanofiber membrane-based glucose testing strips[J]. ANALYST,2014,139(24):6467-6473.
APA Ji, Xiaoyuan,Su, Zhiguo,Wang, Ping,Ma, Guanghui,&Zhang, Songping.(2014)."Ready-to-use" hollow nanofiber membrane-based glucose testing strips.ANALYST,139(24),6467-6473.
MLA Ji, Xiaoyuan,et al.""Ready-to-use" hollow nanofiber membrane-based glucose testing strips".ANALYST 139.24(2014):6467-6473.

入库方式: OAI收割

来源:过程工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。