A Full Aperture Backscattering Light Diagnostic System Installed on the Shenguang-III Prototype Laser Facility

文献类型:期刊论文

作者Xu Tao1; Mei Yu1; Wei Huiyue1; Peng Xiaoshi1; Wang Feng1; Yang Dong1; Liu Shenye1; Yan Yadong2
刊名plasma science & technology
出版日期2014-06-01
卷号16期号:6页码:567-570
关键词backscattering light ICF off-axis parabolic mirror hohlraum targets CPP
ISSN号1009-0630
产权排序2
合作状况国内
英文摘要a full aperture backscattering light diagnostic system (fablds) implemented on the shen guang-iii prototype laser facility is described in the paper. fablds measures both stimulated brillouin scattering (sbs) and stimulated raman scattering (srs) with a series of optical detectors. energy sensors record the integrated energy, and streak cameras coupled with spectrometers measure the temporal spectrum of the backscattering light. this paper provides an overview of the fablds and detailed descriptions of the optical path. special components, including off-axis parabolic mirror, spatial filter and optical light filters, are incorporated along the beam path for purifying the scattering light. several hohlraum targets were employed, including c5ii12 gas-filled targets and empty targets in the experiments. results presented in the paper indicate that the fraction of backscatter light has been obviously shrinked when the laser is smoothed by continuous phase plates (cpp).
WOS标题词science & technology ; physical sciences
类目[WOS]physics, fluids & plasmas
研究领域[WOS]physics
关键词[WOS]national-ignition-facility ; plasma interactions
收录类别SCI ; EI
语种英语
WOS记录号WOS:000337678400005
公开日期2015-03-26
源URL[http://ir.opt.ac.cn/handle/181661/22484]  
专题西安光学精密机械研究所_先进光学仪器研究室
作者单位1.China Acad Engn Phys, Res Ctr Laser Fus, Mianyang 621900, Peoples R China
2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 721000, Peoples R China
推荐引用方式
GB/T 7714
Xu Tao,Mei Yu,Wei Huiyue,et al. A Full Aperture Backscattering Light Diagnostic System Installed on the Shenguang-III Prototype Laser Facility[J]. plasma science & technology,2014,16(6):567-570.
APA Xu Tao.,Mei Yu.,Wei Huiyue.,Peng Xiaoshi.,Wang Feng.,...&Yan Yadong.(2014).A Full Aperture Backscattering Light Diagnostic System Installed on the Shenguang-III Prototype Laser Facility.plasma science & technology,16(6),567-570.
MLA Xu Tao,et al."A Full Aperture Backscattering Light Diagnostic System Installed on the Shenguang-III Prototype Laser Facility".plasma science & technology 16.6(2014):567-570.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。