Evaluation of the systematic shifts of a single-(40)Ca(+)-ion frequency standard

文献类型:期刊论文

作者Huang,Y ; Liu,Q ; Cao,J ; Ou,BQ ; Liu,PL ; Guan,H ; Huang,XR ; Gao,KL
刊名PHYSICAL REVIEW A
出版日期2011
卷号84期号:5页码:053841-53841
产权排序第一
英文摘要Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped Ca-40(+) with a "clock" transition at 729 nm. The overall systematic uncertainty of the 4s S-2(1/2)-3d(2)D(5/2) clock resonance has been characterized to be 7.8 x 10(-16). This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the Ca-40(+) clock exceeds that of Cs.
学科主题原子分子物理学
公开日期2015-07-14
源URL[http://ir.wipm.ac.cn/handle/112942/1903]  
专题武汉物理与数学研究所_2011年以前论文发表(包括2011年)
推荐引用方式
GB/T 7714
Huang,Y,Liu,Q,Cao,J,et al. Evaluation of the systematic shifts of a single-(40)Ca(+)-ion frequency standard[J]. PHYSICAL REVIEW A,2011,84(5):053841-53841.
APA Huang,Y.,Liu,Q.,Cao,J.,Ou,BQ.,Liu,PL.,...&Gao,KL.(2011).Evaluation of the systematic shifts of a single-(40)Ca(+)-ion frequency standard.PHYSICAL REVIEW A,84(5),053841-53841.
MLA Huang,Y,et al."Evaluation of the systematic shifts of a single-(40)Ca(+)-ion frequency standard".PHYSICAL REVIEW A 84.5(2011):053841-53841.