New methods of data calibration for high power-aperture lidar
文献类型:期刊论文
作者 | Guan, Sai1; Yang, Guotao1; Chang, Qihai2; Cheng, Xuewu3; Yang, Yong3; Gong, Shaohua4; Wang, Jihong1 |
刊名 | OPTICS EXPRESS
![]() |
出版日期 | 2013-03-25 |
卷号 | 21期号:6页码:7768-7785 |
英文摘要 | For high power-aperture lidar sounding of wide atmospheric dynamic ranges, as in middle-upper atmospheric probing, photomultiplier tubes' (PMT) pulse pile-up effects and signal-induced noise (SIN) complicates the extraction of information from lidar return signal, especially from metal layers' fluorescence signal. Pursuit for sophisticated description of metal layers' characteristics at far range (80 similar to 130km) with one PMT of high quantum efficiency (QE) and good SNR, contradicts the requirements for signals of wide linear dynamic range (i.e. from approximate 10(2) to 10(8) counts/s). In this article, Substantial improvements on experimental simulation of Lidar signals affected by PMT are reported to evaluate the PMTs' distortions in our High Power-Aperture Sodium LIDAR system. A new method for pile-up calibration is proposed by taking into account PMT and High Speed Data Acquisition Card as an Integrated Black-Box, as well as a new experimental method for identifying and removing SIN from the raw Lidar signals. Contradiction between the limited linear dynamic range of raw signal (55 similar to 80km) and requirements for wider acceptable linearity has been effectively solved, without complicating the current lidar system. Validity of these methods was demonstrated by applying calibrated data to retrieve atmospheric parameters (i.e. atmospheric density, temperature and sodium absolutely number density), in comparation with measurements of TIMED satellite and atmosphere model. Good agreements are obtained between results derived from calibrated signal and reference measurements where differences of atmosphere density, temperature are less than 5% in the stratosphere and less than 10K from 30km to mesosphere, respectively. Additionally, approximate 30% changes are shown in sodium concentration at its peak value. By means of the proposed methods to revert the true signal independent of detectors, authors approach a new balance between maintaining the linearity of adequate signal (20-110km) and guaranteeing good SNR (i.e. 10(4):1 around 90km) without debasing QE, in one single detecting channel. For the first time, PMT in photon-counting mode is independently applied to subtract reliable information of atmospheric parameters with wide acceptable linearity over an altitude range from stratosphere up to lower thermosphere (20-110km). |
WOS标题词 | Science & Technology ; Physical Sciences |
类目[WOS] | Optics |
研究领域[WOS] | Optics |
关键词[WOS] | LASER-RADAR ; PHOTOMULTIPLIERS ; RAYLEIGH ; SYSTEMS ; OZONE ; LINEARITY ; RESONANCE ; AEROSOL ; GAIN |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000316796000121 |
公开日期 | 2015-07-14 |
源URL | [http://ir.wipm.ac.cn/handle/112942/958] ![]() |
专题 | 武汉物理与数学研究所_高技术创新与发展中心 |
作者单位 | 1.Chinese Acad Sci, Natl Space Sci Ctr, State Key Lab Space Weather, Beijing 100190, Peoples R China 2.Tibet Univ Nationalities, Xian 712082, Peoples R China 3.Chinese Acad Sci, Wuhan Inst Phys & Math, State Key Lab Magnet Resonance & Atom & Mol Phys, Wuhan 430071, Peoples R China 4.Hainan Normal Univ, Sch Phys & Elect Engn, Haikou 570000, Peoples R China |
推荐引用方式 GB/T 7714 | Guan, Sai,Yang, Guotao,Chang, Qihai,et al. New methods of data calibration for high power-aperture lidar[J]. OPTICS EXPRESS,2013,21(6):7768-7785. |
APA | Guan, Sai.,Yang, Guotao.,Chang, Qihai.,Cheng, Xuewu.,Yang, Yong.,...&Wang, Jihong.(2013).New methods of data calibration for high power-aperture lidar.OPTICS EXPRESS,21(6),7768-7785. |
MLA | Guan, Sai,et al."New methods of data calibration for high power-aperture lidar".OPTICS EXPRESS 21.6(2013):7768-7785. |
入库方式: OAI收割