Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin
文献类型:期刊论文
作者 | Li M(李萌); Ornelas IM; Liu W(刘巍)![]() ![]() ![]() |
刊名 | ELECTROANALYSIS
![]() |
出版日期 | 2015-06 |
卷号 | 27期号:6页码:1427-1435 |
通讯作者邮箱 | gajin@imech.ac.cn |
关键词 | Dissolved oxygen Electrochemical and optical combination sensor Fe(III) meso-tetra (4-sulfonatophenyl) porphyrin (FeTSPP) Polyaniline Total internal reflection imaging ellipsometry(TIRIE) |
ISSN号 | 1040-0397 |
产权排序 | [Li, Meng; Liu, Wei; Niu, Yu; Jin, Gang] Chinese Acad Sci, NML, Inst Mech, Beijing 100190, Peoples R China; [Ornelas, Isabel M.; Correia, Jorge P.; Viana, Ana S.] Univ Lisbon, Fac Ciencias, CQB, P-1749016 Lisbon, Portugal |
通讯作者 | Jin, G (reprint author), Chinese Acad Sci, NML, Inst Mech, 15 Bei Si Huan West Rd, Beijing 100190, Peoples R China. |
中文摘要 | Polyaniline (PAn) films can be used in an electrochemical and optical combination system to amplify the optical signal for dissolved oxygen (DO) detection. To further improve the sensitivity of PAn film to DO, an oxygen-sensitive molecule, Fe(III) meso-tetera (4-sulfonatophenyl) porphyrin (FeTSPP) is incorporated into PAn during the film generation. Results show that, after incorporating FeTSPP into the PAn matrix, both optical and potentiometric responses to DO are improved. The optimal optical signal is obtained under the application of -2.5 mu A to the modified electrode. Under this applied current, both optical and potentiometric signals show linear relations with the DO concentration within the range of 0.00-4.63 mgL(-1), and the sensitivities for optical and potentiometric signals are 4.18 grayscale units mg(-1)L and 13.39 mVmg(-1) L, respectively. |
分类号 | 二类/Q2 |
类目[WOS] | Chemistry, Analytical ; Electrochemistry |
研究领域[WOS] | Chemistry ; Electrochemistry |
收录类别 | SCI |
原文出处 | http://dx.doi.org/10.1002/elan.201400678 |
语种 | 英语 |
WOS记录号 | WOS:000356604300013 |
源URL | [http://dspace.imech.ac.cn/handle/311007/54969] ![]() |
专题 | 力学研究所_国家微重力实验室 |
推荐引用方式 GB/T 7714 | Li M,Ornelas IM,Liu W,et al. Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin[J]. ELECTROANALYSIS,2015,27(6):1427-1435. |
APA | Li M.,Ornelas IM.,Liu W.,Niu Y.,Correia JP.,...&Jin G.(2015).Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin.ELECTROANALYSIS,27(6),1427-1435. |
MLA | Li M,et al."Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin".ELECTROANALYSIS 27.6(2015):1427-1435. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。