中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A novel 3D correspondence-less method for MRI and Paxinos-Watson atlas of rat brain registration

文献类型:期刊论文

作者Cai, Chao; Ding, Mingyue; Lei, Hao; Cao, Jie; Liu, Ailing; Yang, GZ; Jiang, T; Shen, DG; Gu, L; Yang, J
刊名MEDICAL IMAGING AND AUGMENTED REALITY
出版日期2006
卷号4091页码:269-276
关键词principle component analysis(PCA) Hausdorff distance image registration 3D reconstruction
英文摘要In this paper, a novel three-dimensional registration method for Magnetic Resonance Image (MRI) and Paxinos-Watson Atlas of rat brain involving 3D affine transformations is proposed. For the purpose of adapting to a large range of transform parameters in a high registration accuracy, the registration procedure includes two steps: a principle components analysis (PCA) based coarse registration and a Hausdorff distance based fine registration. Both steps are free from the correspondence of the feature points of MRI and Atlas. We implemented this registration method in a rat brain 3D reconstruction and analysis system. Experiments have demonstrated that this two-step method can be successfully applied to registering the low resolution and noise affection MRI with Paxinos-Watson Atlas of rat brain.
WOS标题词Science & Technology ; Technology ; Life Sciences & Biomedicine
类目[WOS]Computer Science, Artificial Intelligence ; Computer Science, Interdisciplinary Applications ; Computer Science, Theory & Methods ; Radiology, Nuclear Medicine & Medical Imaging
研究领域[WOS]Computer Science ; Radiology, Nuclear Medicine & Medical Imaging
收录类别ISTP ; SCI
语种英语
WOS记录号WOS:000240079500034
公开日期2015-07-28
源URL[http://ir.wipm.ac.cn/handle/112942/4776]  
专题武汉物理与数学研究所_2011年以前论文发表(包括2011年)
作者单位1.Huazhong Univ Sci & Technol, Inst Pattern Recognit & Artificial Intelligence, State Educ Commiss Key Lab Image Proc & Intellige, Wuhan 430074, Peoples R China
2.Chinese Acad Sci, Wuhan Inst Phys & Math, Wuhan 430071, Peoples R China
推荐引用方式
GB/T 7714
Cai, Chao,Ding, Mingyue,Lei, Hao,et al. A novel 3D correspondence-less method for MRI and Paxinos-Watson atlas of rat brain registration[J]. MEDICAL IMAGING AND AUGMENTED REALITY,2006,4091:269-276.
APA Cai, Chao.,Ding, Mingyue.,Lei, Hao.,Cao, Jie.,Liu, Ailing.,...&Yang, J.(2006).A novel 3D correspondence-less method for MRI and Paxinos-Watson atlas of rat brain registration.MEDICAL IMAGING AND AUGMENTED REALITY,4091,269-276.
MLA Cai, Chao,et al."A novel 3D correspondence-less method for MRI and Paxinos-Watson atlas of rat brain registration".MEDICAL IMAGING AND AUGMENTED REALITY 4091(2006):269-276.

入库方式: OAI收割

来源:武汉物理与数学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。