中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Graphene oxide-based microspheres for the dispersive solid-phase extraction of non-steroidal estrogens from water samples

文献类型:期刊论文

作者Wen, Yingying1,2; Niu, Zongliang1; Ma, Yanling2; Ma, Jiping3; Chen, Lingxin2
刊名JOURNAL OF CHROMATOGRAPHY A
出版日期2014-11-14
卷号1368页码:18-25
关键词Non-steroidal estrogens Graphene oxide Dispersive solid-phase extraction High performance liquid chromatography
ISSN号0021-9673
产权排序[Wen, Yingying; Niu, Zongliang] Hainan Med Univ, Sch Trop & Lab Med, Environm Monitoring Lab, Haikou 571199, Peoples R China; [Wen, Yingying; Ma, Yanling; Chen, Lingxin] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc & Ecol Remedia, Yantai 264003, Peoples R China; [Ma, Jiping] Qingdao Technol Univ, Sch Environm & Municipal Engn, Key Lab Environm Engn Shandong Prov, Qingdao 266033, Peoples R China
通讯作者Chen, LX (reprint author), Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc & Ecol Remedia, Yantai 264003, Peoples R China. lxchen@yic.ac.cn
中文摘要A modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method based on the dispersive solid-phase extraction (dSPE) combined with high performance liquid chromatography (HPLC) was developed for the determination of non-steroidal estrogens in water samples. In this study, graphene oxide-based silica microspheres (SiO2@GO) were used as dSPE material for the preconcentration of analytes. HPLC was used for the separation and detection. This was the first time that the synthesized SiO2@GO microspheres were used as stationary phases for the off-line preconcentration of the non-steroidal estrogens in dSPE. dSPE parameters, such as sample pH, volume and type of eluent were optimized. Application of the developed method to analyze spiked lake, reservoir and tap water samples resulted in good recoveries values ranging from 70 to 106% with relative standard deviation values lower than 7.0% in all cases. Limits of detection were in the range of 0.2-6.1 mu g/L. The combined data obtained in this study recommended that the proposed method is very fast, simple, repeatable and accurate for the detection of non-steroidal estrogens. Furthermore, the SiO2@GO microspheres application could potentially be expanded to extract and pre-concentrate other compounds in various matrices. (C) 2014 Elsevier B.V. All rights reserved.
英文摘要A modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method based on the dispersive solid-phase extraction (dSPE) combined with high performance liquid chromatography (HPLC) was developed for the determination of non-steroidal estrogens in water samples. In this study, graphene oxide-based silica microspheres (SiO2@GO) were used as dSPE material for the preconcentration of analytes. HPLC was used for the separation and detection. This was the first time that the synthesized SiO2@GO microspheres were used as stationary phases for the off-line preconcentration of the non-steroidal estrogens in dSPE. dSPE parameters, such as sample pH, volume and type of eluent were optimized. Application of the developed method to analyze spiked lake, reservoir and tap water samples resulted in good recoveries values ranging from 70 to 106% with relative standard deviation values lower than 7.0% in all cases. Limits of detection were in the range of 0.2-6.1 mu g/L. The combined data obtained in this study recommended that the proposed method is very fast, simple, repeatable and accurate for the detection of non-steroidal estrogens. Furthermore, the SiO2@GO microspheres application could potentially be expanded to extract and pre-concentrate other compounds in various matrices. (C) 2014 Elsevier B.V. All rights reserved.
学科主题Biochemical Research Methods; Chemistry, Analytical
研究领域[WOS]Biochemistry & Molecular Biology ; Chemistry
关键词[WOS]PERFORMANCE LIQUID-CHROMATOGRAPHY ; TANDEM MASS-SPECTROMETRY ; WALLED CARBON NANOTUBES ; CLOUD-POINT EXTRACTION ; GAS-CHROMATOGRAPHY ; CAPILLARY-ELECTROPHORESIS ; ENVIRONMENTAL ESTROGENS ; PESTICIDE-RESIDUES ; SEWAGE-SLUDGE ; MICROEXTRACTION
收录类别SCI
语种英语
WOS记录号WOS:000344437500002
源URL[http://ir.yic.ac.cn/handle/133337/8694]  
专题烟台海岸带研究所_中科院海岸带环境过程与生态修复重点实验室
作者单位1.Hainan Med Univ, Sch Trop & Lab Med, Environm Monitoring Lab, Haikou 571199, Peoples R China
2.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc & Ecol Remedia, Yantai 264003, Peoples R China
3.Qingdao Technol Univ, Sch Environm & Municipal Engn, Key Lab Environm Engn Shandong Prov, Qingdao 266033, Peoples R China
推荐引用方式
GB/T 7714
Wen, Yingying,Niu, Zongliang,Ma, Yanling,et al. Graphene oxide-based microspheres for the dispersive solid-phase extraction of non-steroidal estrogens from water samples[J]. JOURNAL OF CHROMATOGRAPHY A,2014,1368:18-25.
APA Wen, Yingying,Niu, Zongliang,Ma, Yanling,Ma, Jiping,&Chen, Lingxin.(2014).Graphene oxide-based microspheres for the dispersive solid-phase extraction of non-steroidal estrogens from water samples.JOURNAL OF CHROMATOGRAPHY A,1368,18-25.
MLA Wen, Yingying,et al."Graphene oxide-based microspheres for the dispersive solid-phase extraction of non-steroidal estrogens from water samples".JOURNAL OF CHROMATOGRAPHY A 1368(2014):18-25.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。