中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Ozonation of trifluralin particles: An experimental investigation with a vacuum ultraviolet photoionization aerosol time-of-flight mass spectrometer

文献类型:期刊论文

作者Meng, Junwang; Yang, Bo; Zhang, Yang; Shu, Xi; Shu, Jinian
刊名JOURNAL OF HAZARDOUS MATERIALS
出版日期2009-12-15
卷号172期号:1页码:390-394
关键词Pesticide Ozonation Trifluralin AMS
中文摘要The ozonation of trifluralin coated on azelaic acid particles is investigated with a vacuum ultraviolet photoionization aerosol time-of-flight mass spectrometer. The suspended trifluralin particles with the mean diameter of 270 nm react with similar to 100 ppm ozone in an aerosol reaction chamber under ambient pressure and room temperature (1 atm. 298 K). The time-of-flight mass spectra of the trifluralin particles and the solid state ozonides are obtained. The assignments of the mass spectra reveal that the major primary ozonides of trifluralin particles are 2,6-dinitro-N-propyl-N-propanoyl-4-(trifluoromethyl) benzamine and 2,6-dinitro-N-(propan-2(and 3)-ol)-N-propyl-4-(trifluoromethyl) benzamine. The major secondary ozonides of trifluralin 2-ethyl-7-nitro-5-(trifluoromethyl) benzimidazole-3-oxide, 2,6-dinitro-N-propyl-4-(trifluoromethyl) benzenamine and 2,6-dinitro-N-(formyl)-N-propyl-4-(trifluoromethyl) benzamine are observed. The primary ozonides are directly resulted from the oxidation of N-propyl groups. The pathways of the primary ozonation are proposed in the paper. (C) 2009 Elsevier B.V. All rights reserved.
WOS记录号WOS:000271346800052
源URL[http://ir.rcees.ac.cn/handle/311016/21440]  
专题生态环境研究中心_大气环境科学实验室
推荐引用方式
GB/T 7714
Meng, Junwang,Yang, Bo,Zhang, Yang,et al. Ozonation of trifluralin particles: An experimental investigation with a vacuum ultraviolet photoionization aerosol time-of-flight mass spectrometer[J]. JOURNAL OF HAZARDOUS MATERIALS,2009,172(1):390-394.
APA Meng, Junwang,Yang, Bo,Zhang, Yang,Shu, Xi,&Shu, Jinian.(2009).Ozonation of trifluralin particles: An experimental investigation with a vacuum ultraviolet photoionization aerosol time-of-flight mass spectrometer.JOURNAL OF HAZARDOUS MATERIALS,172(1),390-394.
MLA Meng, Junwang,et al."Ozonation of trifluralin particles: An experimental investigation with a vacuum ultraviolet photoionization aerosol time-of-flight mass spectrometer".JOURNAL OF HAZARDOUS MATERIALS 172.1(2009):390-394.

入库方式: OAI收割

来源:生态环境研究中心