中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by high performance liquid chromatography-tandem mass spectrometry

文献类型:期刊论文

作者Sun, Li; Yong, Wei; Chu, Xiaogan; Lin, Jin-Ming
刊名JOURNAL OF CHROMATOGRAPHY A
出版日期2009-07-10
卷号1216期号:28页码:5416-5423
关键词Steroidal hormone Water analysis UPLC-MS/MS Solid-phase disk extraction
中文摘要A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17 beta-estradiol, 17 alpha-ethynylestradiol, estriol) and eleven progestogens (17 beta-estradiol-3-benzoate, 19-norethindrone, gestodene. levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with electrospray ionization. Among three types of extraction tested (C(8) SPDE, C(18) SPDE and C(18) SPE), the most satisfactory result was achieved using C(18) SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1 L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5-3.4 ng/L) and excellent linear dynamic range (1.0-50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17 alpha-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L. (C) 2009 Elsevier B.V. All rights reserved.
WOS记录号WOS:000267557800010
源URL[http://ir.rcees.ac.cn/handle/311016/21565]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
推荐引用方式
GB/T 7714
Sun, Li,Yong, Wei,Chu, Xiaogan,et al. Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by high performance liquid chromatography-tandem mass spectrometry[J]. JOURNAL OF CHROMATOGRAPHY A,2009,1216(28):5416-5423.
APA Sun, Li,Yong, Wei,Chu, Xiaogan,&Lin, Jin-Ming.(2009).Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by high performance liquid chromatography-tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY A,1216(28),5416-5423.
MLA Sun, Li,et al."Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by high performance liquid chromatography-tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY A 1216.28(2009):5416-5423.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。