中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Determination of Sialic Acid in Milk and Products Using High Performance Anion-Exchange Chromatography Coupled with Pulsed Amperometric Detection

文献类型:期刊论文

作者Tang Kun-Tian; Liang Li-Na; Cai Ya-Qi; Mou Shi-Fen
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
出版日期2008-11
卷号36期号:11页码:1535-1538
关键词High performance anion exchange chromatography pulsed amperometric detection sialic acid milk
英文摘要A resolved succinct environmental-friendly chromatographic method was developed for the determination of N-acetylneuraminic acid ( Neu5AC ) and N-glycolylneuraminic acid ( Neu5Gc ) in bovine milk and products using high-performance anion exchange chromatography coupled with pulsed amperometric detection. The conditions affecting the separation, detection and sialic acid release from milk were optimized. The separation was carried out on CarboPac PA20 anion-exchange column using 100 mmol/L NaOH, 20 - 300 mmol/L NaAc gradient eluting in 20 min at the flow rate of 0. 5 mL/min. The separation and detection temperature were both at 30 degrees C. The detection was carried out on a gold working electrode. The detection limits were 3. 0 and 1. 8 mu g/L and the linear range of 5 to 500 mu g/L was obtained (25. 0 mu L injection, three times of the baseline noise). The spiked recovery of Neu5AC and Neu5Gc in milk was 88% - 115%.
WOS记录号WOS:000261465900016
源URL[http://ir.rcees.ac.cn/handle/311016/21935]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
推荐引用方式
GB/T 7714
Tang Kun-Tian,Liang Li-Na,Cai Ya-Qi,et al. Determination of Sialic Acid in Milk and Products Using High Performance Anion-Exchange Chromatography Coupled with Pulsed Amperometric Detection[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2008,36(11):1535-1538.
APA Tang Kun-Tian,Liang Li-Na,Cai Ya-Qi,&Mou Shi-Fen.(2008).Determination of Sialic Acid in Milk and Products Using High Performance Anion-Exchange Chromatography Coupled with Pulsed Amperometric Detection.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,36(11),1535-1538.
MLA Tang Kun-Tian,et al."Determination of Sialic Acid in Milk and Products Using High Performance Anion-Exchange Chromatography Coupled with Pulsed Amperometric Detection".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 36.11(2008):1535-1538.