热门
Mixed hemimicelles solid-phase extraction based on cetyltrimethylammonium bromide-coated nano-magnets Fe3O4 for the determination of chlorophenols in environmental water samples coupled with liquid chromatography/spectrophotometry detection
文献类型:期刊论文
作者 | Li, Jidong; Zhao, Xiaoli; Shi, Yali; Cai, Yaqi; Mou, Shifen; Jiang, Guibin |
刊名 | JOURNAL OF CHROMATOGRAPHY A
![]() |
出版日期 | 2008-02-08 |
卷号 | 1180期号:1页码:24-31 |
关键词 | nanoparticles Fe3O4 magnetism mixed hemimicelles solid-phase extraction chlorophenols |
英文摘要 | Mixed hemimicelles solid-phase extraction (SPE) based on cetyltrimethylammonium bromide (CTAB)-coated nano-magnets Fe3O4 was investigated for the preconcentration of four chlorophenols (CPs) in environmental water samples prior to HPLC-spectrophotometry determination in this paper. By the rapid isolating (about 5 min) of Fe3O4 nanoparticles (NPs) through placing a Nd-Fe-B strong magnet on the bottom of beaker, the time-consuming preconcentration process of loading large volume sample in conversional SPE method with a column can be avoided. The unique properties of Fe3O4 NPs such as high surface area and strong magnetism were utilized adequately in the SPE process. This novel separation method produced a high preconcentration rate and factor. A comprehensive study of the adsorption conditions such as the Fe3O4 NPs zeta-potential, CTAB added amounts, pH value, standing time and maximal extraction volume was also presented. Under optimized conditions, four analytes of 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) were quantitatively extracted. The method was then used to determine four CPs in five real environmental water samples. High concentration factors (700) were achieved for each of the analytes, with observed detection limits ranging between 0.11 and 0.15 mu g L-1. The accuracy of method was evaluated by recovery measurements on spiked samples. Good recovery results (83-98%) with satisfactory relative standard deviation (RSD) were achieved. It is important to note that satisfactory preconcentration factors and extraction recoveries for the four CPs were obtained with only a little amount of Fe3O4 NPs (0.1 g) and CTAB (60 mg). To the best of our knowledge, this was the first time a mixed hemimicelles SPE method based on Fe3O4 NPs magnetic separation had been used for the pretreatment of environmental water samples. (c) 2007 Elsevier B.V. All rights reserved. |
WOS记录号 | WOS:000253060900003 |
源URL | [http://ir.rcees.ac.cn/handle/311016/21962] ![]() |
专题 | 生态环境研究中心_环境化学与生态毒理学国家重点实验室 |
推荐引用方式 GB/T 7714 | Li, Jidong,Zhao, Xiaoli,Shi, Yali,et al. Mixed hemimicelles solid-phase extraction based on cetyltrimethylammonium bromide-coated nano-magnets Fe3O4 for the determination of chlorophenols in environmental water samples coupled with liquid chromatography/spectrophotometry detection[J]. JOURNAL OF CHROMATOGRAPHY A,2008,1180(1):24-31. |
APA | Li, Jidong,Zhao, Xiaoli,Shi, Yali,Cai, Yaqi,Mou, Shifen,&Jiang, Guibin.(2008).Mixed hemimicelles solid-phase extraction based on cetyltrimethylammonium bromide-coated nano-magnets Fe3O4 for the determination of chlorophenols in environmental water samples coupled with liquid chromatography/spectrophotometry detection.JOURNAL OF CHROMATOGRAPHY A,1180(1),24-31. |
MLA | Li, Jidong,et al."Mixed hemimicelles solid-phase extraction based on cetyltrimethylammonium bromide-coated nano-magnets Fe3O4 for the determination of chlorophenols in environmental water samples coupled with liquid chromatography/spectrophotometry detection".JOURNAL OF CHROMATOGRAPHY A 1180.1(2008):24-31. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。