Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer
文献类型:期刊论文
作者 | Zhang, ChunMin1,2; Zhao, BaoChang3; Yuan, ZhiLin1,4; Huang, Weijian1,2 |
刊名 | journal of optics a-pure and applied optics
![]() |
出版日期 | 2009-08-01 |
卷号 | 11期号:8 |
关键词 | polarization interference imaging spectroscopy signal-to-noise ratio modulation depth |
英文摘要 | based on radiometry, electromagnetism and polarization theories and fourier transform spectroscopy, an in-depth study is conducted on the signal-to-noise ratio (snr) of the self-developed ultra-compact static polarization interference imaging spectrometer (uspiis) both theoretically and experimentally. the theoretical equations of its snr are deduced. under the paraxial approximation, the curved line of the snr with incidence angle changing is given via computer simulation. how the polarizing directions affect the snr of the uspiis, which is a particular sign of the polarization interference imaging spectrometer, is closely studied. when modulation depth equals 0.6, 0.7, 0.8, 0.9 and 1.0, the curved lines of the snr with changing polarizing directions are given; after that, the optimum value is proposed. under optimum conditions, the changing laws of snr with the detector element are obtained, the same as the theoretical prediction. the theoretical and experimental results both indicate that the novel imaging spectrometer has the advantages of high throughput and high snr under the condition of high modulation depth, which is suitable for aeronautics and space remote sensing and weak signal testing. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | optics |
研究领域[WOS] | optics |
关键词[WOS] | upper atmospheric wind ; savart polariscope ; orientation |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000268692400018 |
公开日期 | 2015-09-01 |
源URL | [http://ir.opt.ac.cn/handle/181661/25229] ![]() |
专题 | 西安光学精密机械研究所_空间光学应用研究室 |
作者单位 | 1.Xi An Jiao Tong Univ, Nonequilibrium Condensed Matter & Quantum Engn La, Xian 710049, Peoples R China 2.Xi An Jiao Tong Univ, Sch Sci, Xian 710049, Peoples R China 3.CAS, Xian Inst Opt & Precis Mech, Xian 710068, Peoples R China 4.Wuhan Res Inst Post & Telecommun, Wuhan 430074, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, ChunMin,Zhao, BaoChang,Yuan, ZhiLin,et al. Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer[J]. journal of optics a-pure and applied optics,2009,11(8). |
APA | Zhang, ChunMin,Zhao, BaoChang,Yuan, ZhiLin,&Huang, Weijian.(2009).Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer.journal of optics a-pure and applied optics,11(8). |
MLA | Zhang, ChunMin,et al."Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer".journal of optics a-pure and applied optics 11.8(2009). |
入库方式: OAI收割
来源:西安光学精密机械研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。