中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer

文献类型:期刊论文

作者Zhang, ChunMin1,2; Zhao, BaoChang3; Yuan, ZhiLin1,4; Huang, Weijian1,2
刊名journal of optics a-pure and applied optics
出版日期2009-08-01
卷号11期号:8
关键词polarization interference imaging spectroscopy signal-to-noise ratio modulation depth
英文摘要based on radiometry, electromagnetism and polarization theories and fourier transform spectroscopy, an in-depth study is conducted on the signal-to-noise ratio (snr) of the self-developed ultra-compact static polarization interference imaging spectrometer (uspiis) both theoretically and experimentally. the theoretical equations of its snr are deduced. under the paraxial approximation, the curved line of the snr with incidence angle changing is given via computer simulation. how the polarizing directions affect the snr of the uspiis, which is a particular sign of the polarization interference imaging spectrometer, is closely studied. when modulation depth equals 0.6, 0.7, 0.8, 0.9 and 1.0, the curved lines of the snr with changing polarizing directions are given; after that, the optimum value is proposed. under optimum conditions, the changing laws of snr with the detector element are obtained, the same as the theoretical prediction. the theoretical and experimental results both indicate that the novel imaging spectrometer has the advantages of high throughput and high snr under the condition of high modulation depth, which is suitable for aeronautics and space remote sensing and weak signal testing.
WOS标题词science & technology ; physical sciences
类目[WOS]optics
研究领域[WOS]optics
关键词[WOS]upper atmospheric wind ; savart polariscope ; orientation
收录类别SCI ; EI
语种英语
WOS记录号WOS:000268692400018
公开日期2015-09-01
源URL[http://ir.opt.ac.cn/handle/181661/25229]  
专题西安光学精密机械研究所_空间光学应用研究室
作者单位1.Xi An Jiao Tong Univ, Nonequilibrium Condensed Matter & Quantum Engn La, Xian 710049, Peoples R China
2.Xi An Jiao Tong Univ, Sch Sci, Xian 710049, Peoples R China
3.CAS, Xian Inst Opt & Precis Mech, Xian 710068, Peoples R China
4.Wuhan Res Inst Post & Telecommun, Wuhan 430074, Peoples R China
推荐引用方式
GB/T 7714
Zhang, ChunMin,Zhao, BaoChang,Yuan, ZhiLin,et al. Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer[J]. journal of optics a-pure and applied optics,2009,11(8).
APA Zhang, ChunMin,Zhao, BaoChang,Yuan, ZhiLin,&Huang, Weijian.(2009).Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer.journal of optics a-pure and applied optics,11(8).
MLA Zhang, ChunMin,et al."Analysis of signal-to-noise ratio of an ultra-compact static polarization interference imaging spectrometer".journal of optics a-pure and applied optics 11.8(2009).

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。