中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Automated Motion Correction for In Vivo Optical Projection Tomography

文献类型:期刊论文

作者Zhu, Shouping4; Dong, Di2; Birk, Udo Jochen1,5; Rieckher, Matthias3; Tavernarakis, Nektarios3; Qu, Xiaochao4; Liang, Jimin4; Tian, Jie2,4; Ripoll, Jorge1
刊名IEEE TRANSACTIONS ON MEDICAL IMAGING
出版日期2012-07-01
卷号31期号:7页码:1358-1371
关键词Helgason-Ludwig consistency condition (HLCC) motion correction optical projection tomography (OPT)
英文摘要In in vivo optical projection tomography (OPT), object motion will significantly reduce the quality and resolution of the reconstructed image. Based on the well-known Helgason-Ludwig consistency condition (HLCC), we propose a novel method for motion correction in OPT under parallel beam illumination. The method estimates object motion from projection data directly and does not require any other additional information, which results in a straightforward implementation. We decompose object movement into translation and rotation, and discuss how to correct for both translation and general motion simultaneously. Since finding the center of rotation accurately is critical in OPT, we also point out that the system's geometrical offset can be considered as object translation and therefore also calibrated through the translation estimation method. In order to verify the algorithm effectiveness, both simulated and in vivo OPT experiments are performed. Our results demonstrate that the proposed approach is capable of decreasing movement artifacts significantly thus providing high quality reconstructed images in the presence of object motion.
WOS标题词Science & Technology ; Technology ; Life Sciences & Biomedicine
类目[WOS]Computer Science, Interdisciplinary Applications ; Engineering, Biomedical ; Engineering, Electrical & Electronic ; Imaging Science & Photographic Technology ; Radiology, Nuclear Medicine & Medical Imaging
研究领域[WOS]Computer Science ; Engineering ; Imaging Science & Photographic Technology ; Radiology, Nuclear Medicine & Medical Imaging
关键词[WOS]FAN-BEAM CT ; COMPUTED-TOMOGRAPHY ; ARTIFACT REDUCTION ; IMAGE QUALITY ; TRANSMISSION ; QUANTIFICATION ; OPTIMIZATION ; MICROSCOPY ; ALGORITHM ; TOOL
收录类别SCI
语种英语
WOS记录号WOS:000305898500003
源URL[http://ir.ia.ac.cn/handle/173211/4065]  
专题自动化研究所_中国科学院分子影像重点实验室
作者单位1.Fdn Res & Technol Hellas FORTH, Inst Elect Struct & Laser, Iraklion 71110, Greece
2.Chinese Acad Sci, Inst Automat, Intelligent Med Res Ctr, Beijing 100190, Peoples R China
3.Fdn Res & Technol Hellas FORTH, Inst Mol Biol & Biotechnol, Iraklion 71110, Greece
4.Xidian Univ, Sch Life Sci & Technol, Xian 710071, Shaanxi, Peoples R China
5.Univ Heidelberg, Kirchhoff Inst Phys, D-69120 Heidelberg, Germany
推荐引用方式
GB/T 7714
Zhu, Shouping,Dong, Di,Birk, Udo Jochen,et al. Automated Motion Correction for In Vivo Optical Projection Tomography[J]. IEEE TRANSACTIONS ON MEDICAL IMAGING,2012,31(7):1358-1371.
APA Zhu, Shouping.,Dong, Di.,Birk, Udo Jochen.,Rieckher, Matthias.,Tavernarakis, Nektarios.,...&Ripoll, Jorge.(2012).Automated Motion Correction for In Vivo Optical Projection Tomography.IEEE TRANSACTIONS ON MEDICAL IMAGING,31(7),1358-1371.
MLA Zhu, Shouping,et al."Automated Motion Correction for In Vivo Optical Projection Tomography".IEEE TRANSACTIONS ON MEDICAL IMAGING 31.7(2012):1358-1371.

入库方式: OAI收割

来源:自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。