热门
Direct determination of chlorophenols in environmental water samples by hollow fiber supported ionic liquid membrane extraction coupled with high-performance liquid chromatography
文献类型:期刊论文
作者 | Peng, Jin-Feng ; Liu, Jing-Fu ; Hu, Xia-Lin ; Jiang, Gui-Bin |
刊名 | JOURNAL OF CHROMATOGRAPHY A
![]() |
出版日期 | 2007-01-19 |
卷号 | 1139期号:2页码:165-170 |
关键词 | supported liquid membrane ionic liquids chlorophenols high-performance liquid chromatography |
英文摘要 | The 1-octyl-3-methylimiclazolium hexafluorophosphate ([CsMIM][PF6]) ionic liquid was immobilized in the pores of a polypropylene hollow fiber for hollow fiber-protected liquid-phase microextraction. Analytes including 4-chlorophenol (4-CP), 3-chorophenol (3-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6-trichlorophenol (2,4,6-TCP) were extracted into this ionic liquid membrane, and back extracted into 10 mu L sodium hydroxide acceptor solution in the lumen of the hollow fiber. Then, the acceptor solution was withdrawn into the high-performance liquid chromatography (HPLC) microsyringe connected to the hollow fiber, and directly injected into the HPLC system for analysis. Some parameters that might affect the extraction efficiency were optimized, and low detection limits (0.5 mu g L-1 for 4-CP, 3-CP, DCP and 1.0 mu g L-1 for TCP) were obtained. Good repeatability was achieved because of the stability of the hollow fiber-supported ionic liquid membrane. The proposed procedure was applied for direct determination of the four chlorophenols in some real water samples including groundwater, river water, wastewater and tap water. All of the four chlorophenols in these water samples were under the limits of determination, and the recoveries were in the range of 70.0-95.7% at 5 mu g L-1 spiked level. (c) 2006 Elsevier B.V. All rights reserved. |
WOS记录号 | WOS:000243574900002 |
源URL | [http://ir.rcees.ac.cn/handle/311016/22446] ![]() |
专题 | 生态环境研究中心_环境化学与生态毒理学国家重点实验室 |
推荐引用方式 GB/T 7714 | Peng, Jin-Feng,Liu, Jing-Fu,Hu, Xia-Lin,et al. Direct determination of chlorophenols in environmental water samples by hollow fiber supported ionic liquid membrane extraction coupled with high-performance liquid chromatography[J]. JOURNAL OF CHROMATOGRAPHY A,2007,1139(2):165-170. |
APA | Peng, Jin-Feng,Liu, Jing-Fu,Hu, Xia-Lin,&Jiang, Gui-Bin.(2007).Direct determination of chlorophenols in environmental water samples by hollow fiber supported ionic liquid membrane extraction coupled with high-performance liquid chromatography.JOURNAL OF CHROMATOGRAPHY A,1139(2),165-170. |
MLA | Peng, Jin-Feng,et al."Direct determination of chlorophenols in environmental water samples by hollow fiber supported ionic liquid membrane extraction coupled with high-performance liquid chromatography".JOURNAL OF CHROMATOGRAPHY A 1139.2(2007):165-170. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。